Related Experiment Video
Updated: Jan 16, 2026

Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM
Published on: December 1, 2016
Enhanced calibration method for wall-mounted RGSC cameras: Mitigating baseline drift caused by CT couch sagging
Jiangtao Wang1, Jinyou Hu1, Xiangxiang Liu1
1Cancer Center, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, Sichuan, China.
This study introduces an improved calibration technique to reduce errors in respiratory gating systems caused by CT couch sagging. The new method significantly decreases baseline drift, enhancing tumor motion management accuracy.
Area of Science:
- Medical Imaging Physics
- Radiotherapy Technology
- Image-Guided Therapy
Background:
- CT couch sagging introduces noise into respiratory signals, affecting tumor motion management accuracy.
- Accurate respiratory gating relies on precise tracking of patient motion during CT scans.
Purpose of the Study:
- To present an enhanced calibration method for the wall-mounted Respiratory Gating for Scanner (RGSC) camera.
- To reduce calibration uncertainty and mitigate baseline drift caused by CT couch sagging.
Main Methods:
- A 70kg weight simulated patient load on the CT table.
- Reflector blocks were precisely positioned using a laser alignment system and CT console.
- Calibration measurements were performed at nine points across lateral and longitudinal positions, with Varian's method used for comparison.
Main Results:
- Block positioning uncertainty was reduced to the sub-millimeter level.
- Residual baseline drift was significantly mitigated from 2.84 ± 0.22 mm to 0.64 ± 0.06 mm (p<0.001).
Conclusions:
- The proposed calibration method robustly minimizes positioning uncertainty and reduces baseline drift from CT couch sagging.
- This enhances the repeatability and accuracy of wall-mounted camera calibration.
- The method's versatility supports both wall- and ceiling-mounted cameras, expanding clinical utility.
More Related Videos
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Common Leveling Mistakes and Errors
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Calibration Curves: Correlation Coefficient

