Related Experiment Video
Updated: Jan 16, 2026

In vitro Cell Culture Model for Toxic Inhaled Chemical Testing
Published on: May 8, 2014
Connexin-hemichannels-mediated ATP release causes lung injury following chlorine inhalation
Ahmed Lazrak1, Zhihong Yu1, Sadis Matalon1
1Division of Molecular and Translational Biomedicine, Department of Anesthesiology and Perioperative Medicine, Pulmonary Injury and Repair Center, Heersinck School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, United States.
Abstract:
Chlorine (Cl2) is a highly reactive halogen gas that undergoes rapid hydrolysis in lung epithelial lining fluid (ELF) upon inhalation, forming hypochlorous acid (HOCl) and hydrochloric acid (HCl). These products subsequently, through chemical reactions, modify the structure and the function of membrane proteins. Herein, we investigated the effects of Cl2 on connexin-hemichannels and the release of ATP in the ELF. Adult C57BL/6 mice were subjected to 400 ppm Cl2 for 30 min. Subsequent analysis revealed a marked increase in ATP levels within the BAL, with concentrations reaching 43.952 ± 9.553 nM at 2 h and 30.554 ± 7.383 nM at 24 h post exposure, relative to control. In addition, at 24 h post exposure, the lung wet/dry (W/D) ratio significantly increased from 4.48 ± 0.142 to 5.067 ± 0.359, whereas alveolar fluid clearance (AFC) decreased from 0.249 ± 0.019 to 0.145 ± 0.018. Electrophysiological recordings in alveolar type 2 (AT2) cells revealed reduced open probabilities (Po) of both ENaC (4 pS) and a cation channel (18 pS), declining from 0.323 ± 0.021 and 0.202 ± 0.022 to 0.151 ± 0.042 and 0.091 ± 0.019, respectively. Instillation of 50 µL of 100 µg/mL Gap27-a connexin mimetic peptide selectively inhibiting connexin-hemichannels-administered 30 min post exposure, restored ATP to control, normalized the W/D ratio, improved AFC, and reestablished ENaC function. Moreover, Gap27 normalized airway resistance following methacholine challenge. In human airway smooth muscle cells (hASMCs), 100 μM ATP induced [Formula: see text] elevation and depolarized Vm to -40 mV, with both effects partially reversed by P2X7R inhibitor, A804598.NEW & NOTEWORTHY Inhaled chlorine gas reacts with lung epithelial lining fluid to form hypochlorous and hydrochloric acids that alter membrane protein structure and function. Under oxidative stress, connexin hemichannels open, releasing ions and metabolites, such as ATP. The released ATP signals danger, cell death, and tissue injury. Early administration of Gap27, a connexin-hemichannel inhibitor, at 30 min post exposure preserves ENaC function and prevents the subsequent development of pulmonary edema. These compelling findings underscore a promising therapeutic strategy.
Related Concept Videos
Pneumothorax-I
Pneumothorax can be even further classified as spontaneous, traumatic, and tension pneumothorax.
Toxic Reactions: Overview
Toxicity falls into two primary categories: local and systemic.
Local toxicity appears at the exposure site, such as protein denaturation caused by caustic substances.
In contrast, systemic toxicity requires the toxic agent's absorption and distribution,...
Acute Respiratory Failure-III
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Types of Toxins
Air pollutants, primarily gases, pose significant threats to respiratory health, leading to conditions like hypoxia, lung cancer, and in extreme cases, death.
Environmental pollutants like...
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation

