Quantum LBP-driven heart sound analysis with quality assessment in real-world noisy environments
Subhashree Sahoo1, Puneet Kumar Jain1
1Department of Computer Science & Engineering, National Institute of Technology Rourkela, Odisha, 769008, India.
Background And Objective:
Cardiovascular disease (CVD) is a major global health concern with increasing prevalence. While electrocardiography (ECG) and echocardiography offer high accuracy, their reliance on specialized equipment and trained personnel makes them costly and less accessible in rural areas. In contrast, the Phonocardiography (PCG) provides a more affordable alternative via capturing heart sound signals using a stethoscope. However, PCG analysis is often compromised by environmental noise. Most existing methods address this issue with denoising techniques, which can inadvertently suppress vital heart sound components. To address this challenge, the objective of this work is to develop a computationally efficient and noise-resilient method for PCG classification.
Methods:
The proposed approach introduces a quality assessment metric (PCGQA) to select the least noisy subsequences for further processing. For noise-robust feature extraction, an Enhanced Quantum Local Binary Pattern (EQLBP) method is employed, which adaptively selects reference pixels and extracts uniform patterns from the signal spectrogram to mitigate noise effects. In addition, Discrete Wavelet Transform (DWT) features are extracted to capture multi-resolution time-frequency characteristics, complementing the local texture features obtained from EQLBP. The combined feature set is then used to train conventional machine learning models.
Results:
The proposed method was evaluated using 10-fold cross-validation on two publicly available datasets: CinC-2016 and HSM-2018. On CinC-2016, it achieved an accuracy of 97.22%, precision of 98.29%, recall of 98.63%, and an F1-score of 98.46%. On HSM-2018, the method obtained an accuracy of 98.70%, precision of 99.05%, recall of 99.00%, and an F1-score of 99.00%. These results highlight the superior performance of the proposed approach compared to existing methods.
Conclusions:
With its computational efficiency and robust performance, the proposed method is well-suited for out-of-clinic applications, particularly in rural and remote areas where access to advanced diagnostic tools is limited.
Related Concept Videos
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.