Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Feasibility of the dynamic EIT technique for non-invasive monitoring of V/Q: a preliminary study
Junyao Li1, Yitong Guo1,2, Mingxu Zhu1
1Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Department of Biomedical Engineering, Air Force Medical University, Fourth Military Medical University, Xi'an, 710032, China.
Abstract:
Ventilation/perfusion (V/Q) matching represents a crucial indicator of lung function. The current for assessing V/Q in a clinical setting are inadequate for bedside monitoring purposes. They are characterised by invasiveness and an increased risk of infection. Accordingly, the present study was based on a high-performance electrical impedance tomography (EIT) system developed by our team, with the objective of exploring the feasibility of using it for non-invasive assessment of V/Q at the bedside. This was achieved by acquiring and imaging pulmonary blood flow pulsation signals and combining them with pulmonary ventilation impedance information. Continuous lung EIT imaging data were acquired at 40 fps through different body positions and breath-holding in anaesthetised domestic pigs (N = 8, 17.50 ± 1.51 kg). By analysing the blood flow pulsation impedance information, lung perfusion-related data were extracted and combined with lung ventilation impedance data to establish a pulsatility V/Q assessment method. Furthermore, the monitoring of pulmonary perfusion using hypertonic saline (5 ml of 10% NaCl) was employed as a control experiment. The results demonstrate that the V/Q results obtained through the utilisation of both methodologies exhibit a notable degree of variability in response to alterations in body position and the state of breath holding. The V/Q results obtained using the pulsatility method and the saline method were subjected to analysis using the Bland-Altman agreement test. During end-expiration breath-holding in the supine position, the results were as follows: 95% CI = 2.36% to 10.26%, bias = 6.309%. During end-inspiration breath-holding in the supine position, the results were as follows: 95% CI = 0.07% to 12.23%, bias = 6.150%. During end-expiration breath-holding in the prone position, the results were as follows: 95% CI = -0.40% to 14.43%, bias = 7.014%. During end-inspiration breath-holding in the prone position, the results were as follows: 95% CI = 1.92% to 11.17%, bias = 6.541%. Moreover, a Pearson correlation analysis revealed a significant correlation between the V/Q match% of the two methods (r = 0.7248; 95% CI = 0.50% to 0.86%; p < 0.0001). Consequently, EIT imaging based on the pulsatility method is capable of assessing V/Q alterations resulting from diverse body positions and changes during breath-holding. This approach offers a novel concept for bedside monitoring of patients.
More Related Videos
05:56Author Spotlight: Enhancing Diagnostic Strategies and Biomarker Development for Comprehensive Lung Function Analysis
Published on: August 9, 2024
08:26Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...