Related Experiment Video
Updated: Jan 16, 2026

A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
Using Chlorhexidine-Coated Dialysis Catheter Caps to Reduce Central Venous Dialysis Catheter Infection Rates: A
Rosemary Olivier1, Claudia Skinner2, Todd Bloom3
1Rosemary Olivier is a critical care clinical coordinator at Providence St. Jude Medical Center, Fullerton, California.
Background:
Many patients with end-stage kidney disease begin dialysis therapy with central venous dialysis catheters, significantly increasing the risk of dialysis catheter-related bloodstream infection. Bloodstream infections are among the most severe harm events affecting patients receiving dialysis.
Local Problem:
In 2023, the dialysis catheter-related central line [catheter]-associated bloodstream infection (CLABSI) rate at an acute care medical center in southern California was thrice the national benchmark. This quality improvement project aimed to decrease this rate by adding chlorhexidine-coated dialysis catheter caps to standard care.
Methods:
Using the Knowledge to Action model, the medical center made a dialysis catheter-related CLABSI reduction practice change. Preimplementation and postimplementation monthly aggregate data were collected for dialysis catheter-related CLABSIs, central venous dialysis catheter days, and dialysis catheter-related infection rates. One-on-one dialysis staff simulation training and process compliance audits ensured intervention fidelity. The intervention was replacement of nonchlorhexidine dialysis catheter caps with chlorhexidine-coated dialysis catheter caps for patients with central venous dialysis catheters.
Results:
An 8-week preimplementation period included 119 patients, 561 dialysis therapies, 934 central dialysis catheter days, and 2 dialysis catheter-related CLABSIs (2.14 infections per 1000 catheter days). An 8-week postimplementation period included 128 patients, 583 dialysis therapies, 897 central dialysis catheter days, and 0 dialysis catheter-related CLABSIs; no dialysis catheter-related CLABSIs occurred during postimplementation sustainability assessment (24 weeks total).
Conclusions:
Use of chlorhexidine-coated dialysis catheter caps led to clinically significant results among patients receiving dialysis with central catheters at an acute care medical center.
Related Concept Videos
Hand hygiene
Hand washing...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Endocarditis IV: Nursing Management
Hemodialysis II: Procedure and Complications
Continuous Renal Replacement Therapy

