Related Experiment Video
Updated: Jan 16, 2026

Whole-body PET/MRI of Pediatric Patients: The Details That Matter
Published on: December 19, 2017
Clinical Evaluation of BSREM Reconstruction in Pediatric Oncology Using [18F]FDG PET/CT
Nicholas A Shkumat1,2, Reza Vali3,2, Amer Shammas3,2
1Department of Diagnostic and Interventional Radiology, The Hospital for Sick Children, Toronto, Ontario, Canada; and nicholas.shkumat@sickkids.ca.
Abstract:
Recent technologic advancements in PET, including silicon photomultipliers and block-sequential regularized expectation maximization (BSREM) tools, have allowed for renewed assessment of the optimal acquisition and reconstruction parameters in pediatric imaging. This work evaluates the performance of BSREM reconstruction and varied count density (CD) in digital [18F]FDG PET/CT to investigate the feasibility of reducing the injected activity or duration of acquisition in children with cancer. Methods: Five hundred unique reconstructions from 20 pediatric patients evaluated with PET/CT per clinical standard of care (SOC) were included in this retrospective study. Three-dimensional, whole-body imaging was acquired on a silicon photomultiplier PET/CT system in list mode with time-of-flight modeling. Imaging volumes were reconstructed with varying time per bed position (180, 120, 90, 60, and 45 s) to simulate a range of CDs using conventional iterative techniques (ordered-subset expectation maximization) and BSREM with varied regularization strength (β, 175-700). Two pediatric nuclear medicine physicians individually scored all studies, with patient information, reconstruction method, and CD concealed, rating technical quality and overall diagnostic satisfaction on a 5-point Likert scale. Quantitative SUV measurements on all reconstructions were compared with the clinical SOC. Results: Reconstruction with BSREM with a β of 500 or greater significantly improved overall scores across all CDs when compared with ordered-subset expectation maximization. Noise performance improved after application of a higher regularization parameter. Spatial resolution (sharpness) was greatest with a β of 350. Mean overall image quality at 25% CD using a β of 500 or greater was considered diagnostic. Mean liver and blood-pool SUV-to-noise ratio performed best with the highest β and CD. SUVmax behavior was complex, varying with reconstruction strength and CD, with measurements at β of 500 or greater differing from the SOC by no more than 15% across all CDs, and specific combinations varying by 10% or less. Conclusion: Clinical evaluation of whole-body [18F]FDG PET/CT in pediatric patients was diagnostic at all reductions in CD when using BSREM with a β of 500 or greater. Quantitative performance was variable, yet SUVmax differences of 10% or less were achievable with the appropriate selection of acquisition and reconstruction parameters. This study found that customized imaging parameters can reduce injected activity (radiation dose) and imaging time to best suit the pediatric patient.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)