Related Experiment Video
Updated: Jan 16, 2026

Minimally Invasive Thumb-sized Pterional Craniotomy for Surgical Clip Ligation of Unruptured Anterior Circulation Aneurysms
Published on: August 11, 2015
Mitomycin C-immobilized silver nanoparticle-loaded polycaprolactone membrane for temporary scalp expansion after
Kai-Lun Liu1, Ya-Jyun Liang1, Kuo-Hsiang Hung2
1Department of Biomedical Engineering College of Medicine and College of Engineering, National Taiwan University Taipei Taiwan.
Abstract:
Malignant cerebral edema (MCE) represents a significant medical emergency characterized by unmanageable intracranial pressure (ICP), frequently arising as a consequence of traumatic brain injury (TBI) or ischemic stroke. Decompressive craniectomy (DC) is a prevalent surgical procedure employed to mitigate elevated ICP by excising a segment of the skull to enhance intracranial volume. Nevertheless, in patients suffering from MCE, the limited capacity for expansion of the scalp subsequent to DC may lead to sustained elevated ICP and complications including wound-edge necrosis, cerebrospinal fluid leakage, and infection. This investigation seeks to formulate a biocompatible, antibacterial, and anti-adhesive membrane intended for temporary scalp expansion following DC, thereby addressing these pressing concerns. The proposed membrane comprises polycaprolactone (PCL) augmented with silver nanoparticles (AgNPs) to confer antibacterial properties and is further immobilized with Mitomycin C (MMC) to minimize tissue adhesion, thereby facilitating more straightforward removal. The selection of PCL was predicated upon its remarkable mechanical strength and ductility, which make it suitable for withstanding intracranial edema and facilitating the suturing protocol. The AgNPs were synthesized through a green synthesis methodology employing epigallocatechin gallate (EGCG) to ensure environmental sustainability and the stability of the resultant nanoparticles. MMC, known for its anti-proliferative attributes, was affixed to the PCL surface via oxygen plasma treatment, thereby enhancing the anti-adhesive properties of the membrane. This study evaluates the mechanical characteristics, antibacterial effectiveness, anti-adhesive capabilities, and biocompatibility of the PCL/AgNPs/MMC membrane, thereby demonstrating its potential to improve outcomes in DC procedures by increasing intracranial volume and reducing postoperative complications.
More Related Videos
08:42The DREAM Implant: A Lightweight, Modular, and Cost-Effective Implant System for Chronic Electrophysiology in Head-Fixed and Freely Behaving Mice
Published on: July 26, 2024
06:14Expansion of Two-dimension Electrospun Nanofiber Mats into Three-dimension Scaffolds
Published on: January 7, 2019