Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
Comparison of quantitative lung measures in low dose energy-integrating detector and photon-counting detector chest
Natally ALArab1, Marrissa McIntosh1, Junfeng Guo1
1Department of Radiology, Carver College of Medicine, University of Iowa, Iowa City, IA, United States of America.
Abstract:
Photon-counting detector (PCD) computed tomography (CT) promises improved resolution and contrast at reduced x-ray dose compared to energy-integrating detector (EID) CT. Our objective is to determine the parameters that achieve robust accuracy of quantitative measures in chest PCD-CT studies compared to quantitative EID-CT at low CT dose. The Kyoto LUNGMAN chest phantom with preserved lung tissue core and NIST-calibrated foam density standards (4-20 lbs.), and the COPD Lung Phantom II with six airways of various outer and inner diameters, were scanned using PCD-CT (NAEOTOM Alpha) and EID-CT (SOMATOM Force) with a target CT dose index (CTDIvol) of 2.2 mGy to match that specified for ongoing longitudinal quantitative chest CT studies of chronic lung disease. Mean density of foam inserts in the Kyoto phantom and mean lumen area (LA) and wall thickness (WT) of COPD Lung Phantom II were automatically segmented, analyzed, and compared using the root mean squared error (RMSE). Contrast-to-noise (CNR) and signal-to-noise (SNR) ratios were also automatically calculated. Large (11.2 mm) and small (5.5 mm) airway LA and WT in the lung tissue core of the Kyoto phantom were semi-automatically measured. PCD-CT with the Qr40 kernel yielded superior foam density accuracy (RMSE: 6.1-7.8 HU) compared to EID-CT (RMSE: 9.7 HU). Q+UHR mode with Qr64 and a 1024 × 1024 matrix achieved the highest airway accuracy (RMSE <1.8 mm2for LA and <0.3 mm for WT). However, these protocols showed increased variability in tracheal air measurements (SD up to ±9 HU), indicating a trade-off between higher spatial resolution and measurement repeatability. At equivalent low radiation dose (2.2 mGy CTDIvol), PCD-CT outperforms EID-CT in quantitative accuracy for foam density and airway measurements, with comparable SNR and CNR. These results support the use of PCD-CT for quantitative lung imaging in longitudinal studies, provided reconstruction settings are selected to balance accuracy and repeatability.
More Related Videos
08:23Author Spotlight: Advancing Lung Disease Research with Free-Breathing Hyperpolarized Xenon-129 MRI
Published on: November 10, 2023
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT