Development of a novel artificial intelligence algorithm for interpreting fetal heart rate and uterine activity data
Rohit Pardasani1, Renee Vitullo1, Sara Harris1
1GE HealthCare, Chicago, IL, United States.
Introduction:
Cardiotocography (CTG) assesses fetal well-being through measurements of fetal heart rate (FHR) and uterine activity (UA). Manual visual assessment of fetal tracings is variable due to the subjective nature of their interpretation. Artificial intelligence (AI) using automatic signal processing may be leveraged to support consistent, comprehensive interpretations. This study demonstrated the development and training of a novel AI algorithm that analyzes and interprets certain clinical events and parameters calculated during labor to assist with clinical decisions.
Methods:
Fetal tracings sourced from 19 birthing centers through a US-based healthcare delivery organization were clinically interpreted, labeled, quality checked, and ratified by clinicians to be included in the study. The algorithm using deep learning and rule-based techniques was developed to identify segments of interest (accelerations, decelerations, and contractions). A three parallel one-dimensional Unet design with two inputs (FHR and UA) and one channel output each (for accelerations, decelerations, and contractions) was selected as the final architecture. Algorithm performance was evaluated through recall (sensitivity), precision, F1 score, and duration and numerical ratios.
Results:
A total of 133,696 patient files were used to create fetal tracings. After the exclusion, labeling, and ratification processes, the final datasets included 1,600 tracings for training, 421 for validation, and 591 for testing. The model provided promising performance and achieved F1 scores of 0.803 for accelerations, 0.520 for decelerations, and 0.868 for contractions on the final test set, with a 91.5% predicted baseline accuracy (difference of ≤5 bpm) compared to clinician interpretation.
Conclusion:
This study demonstrates the successful development of a novel AI algorithm utilizing FHR and UA data to analyze and interpret fetal tracing events and parameters. The algorithm may have potential to enhance patient care by supporting bedside clinician CTG interpretation.
Related Concept Videos
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...