Related Experiment Video
Updated: May 7, 2026

Diffusion Imaging in the Rat Cervical Spinal Cord
Published on: April 7, 2015
ESR Essentials: diffusion-weighted MRI-practice recommendations by the European Society for Magnetic Resonance in
Marco Palombo1,2, Benedetta Bodini3,4, Francesco Grussu5
1Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, UK. palombom@cardiff.ac.uk.
Abstract:
Diffusion-weighted imaging (DWI) offers critical insights into tissue microstructure through the assessment of water molecule random displacements and plays a central role in the assessment of neoplastic and non-neoplastic diseases. To successfully implement and use DWI in clinical practice, guidelines for acquisition, interpretation of image contrast and of artefacts should be followed, taking the disease process and body part into account. We recommend covering a b-value range of 0-1000 s/mm2 in the brain (along at least six directions for white matter), and 50-800 s/mm2 in the body. Available acquisition acceleration options should be used to reduce repetition time (TR), echo time (TE), and echo-planar imaging (EPI) distortions, while considering the penalty in signal-to-noise ratio (SNR) and image sharpness. DW images and the apparent diffusion coefficient (ADC) map should be read jointly for the clinical interpretation. Areas of slower diffusion are hyperintense on DW images and hypointense on the ADC map, and vice versa. Magnetic susceptibility distortions and signal drop-outs or pile-ups are particularly pronounced at air-tissue or metal-tissue interfaces and may obscure areas of interest or hinder the co-localisation with structural scans. By following these guidelines and recommendations, radiologists and imaging professionals can enhance diagnostic accuracy, reduce variability, and maximise the clinical value of DWI across diverse applications. KEY POINTS: This article provides an overview of DWI principles, clinical applications, potential pitfalls, and emerging advances, alongside expert recommendations for optimal implementation. We provide key considerations tailored to specific applications (neuro and whole-body imaging), including protocol optimisation, adherence to established guidelines, and quality assurance measures to minimise artefacts and ensure reproducibility. By following the guidelines and recommendations summarised in this work, radiologists and imaging professionals can enhance diagnostic accuracy, reduce variability, and maximise the clinical value of DWI across diverse applications.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI

