Fat-Water Phantoms for Magnetic Resonance Imaging Validation: A Flexible and Scalable Protocol
Published on: September 7, 2018
Fast water/fatT2and PDFF mapping via multiple overlapping-echo detachment acquisition and deep learning
Qing Lin1, Weikun Chen1, Taishan Kang2
1Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen 361105, People's Republic of China.
None:
Objective.Rapid and accurate quantitative assessment of muscle tissue characteristics is valuable for the diagnosis and monitoring of neuromuscular diseases (NMDs). Quantitative magnetic resonance imaging (MRI) enables non-invasive assessment of muscle pathology by using waterT2values to assess muscle damage and proton density fat fraction (PDFF) to quantify fat infiltration. However, conventional methods for simultaneous water-fat separation andT2quantification often require long acquisition times. This study aims to develop an ultrafast method for simultaneous water-fat separation andT2quantification.Approach.A novel water-fat separation framework that combines chemical shift encoding with the multiple overlapping-echo detachment sequence (CSE-MOLED) was proposed. Synthetic training data and deep learning-based reconstruction were employed to address challenges in water-fat separation, including the complex multi-peak spectral characteristic of fat and the non-idealities in MRI acquisition. All experiments, including phantom andin vivoscans, were performed on a 3T MRI scanner. Thein vivoexperiments focused on the human thigh and involved five healthy volunteers, one subject with muscle atrophy, and one with muscle damage. The CSE-MOLED sequence was acquired with a spatial resolution of 1.72 mm × 1.72 mm × 5 mm. For reference, mDixon-TSE (Turbo Spin Echo) was performed to generate PDFF, waterT2, and fatT2maps.Main results.In numerical experiments (T2range: water 19-160 ms, fat 15-160 ms; PDFF range: 14%-100%), theR2values were all 0.999 for waterT2, fatT2, and PDFF, with average percentage errors of 3.16%, 0.98%, and 0.78%, respectively. In phantom experiments (T2range: water 35-125 ms, fat 36-47 ms; PDFF range: 14-36%), theR2values were 0.995, 0.733, and 0.996 for waterT2, fatT2, and PDFF, with average percentage errors of 5.56%, 2.93%, and 1.77%, respectively. High repeatability (coefficient of variation <2.0%) was achieved in both phantom andin vivoexperiments. In patient scans, CSE-MOLED successfully distinguished between fat infiltration and muscle damage.Significance. CSE-MOLED simultaneously obtainsT2and proton density maps for both water and fat, along withT2-corrected PDFF map, in 162 ms per slice of acquisition time, offering the potential to enhance the diagnostic accuracy of NMDs without increasing the clinical scanning burden.