CT vs. MRI-based synthetic CT: accuracy of thoracic and lumbar pedicle screw placement using 3D-printed guides
Jules Cool1,2, Peter P G Lafranca3, Joëll Magré3,4
1Department of Orthopaedic Surgery and Sports Medicine, Amsterdam University Medical Centers, Amsterdam, Netherlands. j.cool@amsterdamumc.nl.
Purpose:
3D-printed patient-specific guides enable accurate pedicle screw placement in the treatment of paediatric spinal deformities. MRI-based synthetic CT (sCT) eliminates the radiation exposure associated with the preoperative planning CT, while still providing detailed bony morphology. It may therefore offer a radiation-free method for pedicle screw navigation. Thus, the aim of this study was to compare the accuracy of thoracic and lumbar pedicle screw placement using 3D-printed guides based on conventional CT versus sCT.
Methods:
Full-spine MRI and CT images of four human cadaveric spines were obtained, followed by AI-generation of sCTs, the digital planning of pedicle screws and 3D-printed guide manufacturing. A total of 62 K-wires were inserted, 30 sCT-based and 32 CT-based. Accuracy was evaluated by superimpose analysis of planned and achieved trajectories, and by the postoperative grading of the cortical breach rate using the Gertzbein-Robbins classification, based on projected screws along the K-wires.
Results:
Median translational entry-point deviations were 1.0 mm vertically and 0.5 mm horizontally for both sCT-based guides and CT-based guides. Angular deviations in the axial plane were 1.0˚ for sCT and 0.9˚ for CT. In the sagittal plane these were 1.8˚ and 2.1˚, respectively. No significant differences were observed between sCT and CT. Grading of pedicle's cortical breach showed no severe malposition for both sCT- and CT-based guides.
Conclusion:
sCT matched the accuracy of conventional CT in providing source data for personalized 3D-printed guides for thoracic and lumbar pedicle screw placement in terms of translational- and angular deviations, and cortical breach rates in this cadaveric study.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography