Related Experiment Video
Updated: Jan 16, 2026

An Efficient and Reproducible Protocol for Distraction Osteogenesis in a Rat Model Leading to a Functional Regenerated Femur
Published on: October 23, 2017
Radiological and Functional Outcomes Following Distal Radius Fixation With a Volar Locking Plate
Ahmed S Nasir1, Kashif Memon2, Mahmoud Mersal2
1Hand Surgery, Queen Elizabeth Hospital Birmingham, Birmingham, GBR.
Patient satisfaction after distal radius fracture fixation with volar locking plates is linked to articular surface collapse. Higher articular surface distance correlated with greater patient satisfaction at six weeks.
Area of Science:
- Orthopedic surgery
- Traumatology
- Radiology
Background:
- Distal radius fractures are increasingly common due to rising life expectancy.
- Current treatments include closed reduction with casting or open reduction with volar locking plates.
- Assessing patient satisfaction and radiographic outcomes is crucial for treatment evaluation.
Purpose of the Study:
- To evaluate patient satisfaction following volar locking plate fixation for distal radius fractures.
- To assess the degree of articular surface collapse at six weeks post-surgery.
- To correlate radiographic parameters with patient-reported satisfaction.
Main Methods:
- A study included 149 patients undergoing volar locking plate fixation for distal radius fractures.
- Radiographic measurements (radial height, radial inclination, volar tilt, articular surface to distal screw distance) were taken preoperatively, intraoperatively, and at six weeks.
- Patient satisfaction was assessed at the final follow-up.
Main Results:
- Significant improvements were observed in distal radius radiological parameters post-fixation (P < 0.05).
- A significant collapse of the articular surface (decrease in articular surface to distal screw distance) was noted at six weeks (P < 0.05).
- Patients satisfied with the outcome had a greater mean articular surface to distal screw distance (4.84 mm) compared to unsatisfied patients (4.50 mm).
Conclusions:
- Volar locking plate fixation significantly improves radiological parameters for distal radius fractures at six weeks.
- Articular surface collapse is a significant finding at six weeks post-fixation.
- Maintaining a greater articular surface to distal screw distance is associated with higher patient satisfaction.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...