Comparison of the suitability of different sampling techniques for exhaled volatile organic compounds in dairy cows
Julia Eichinger1, Lucie Katharina Katharina Tintrop2, Raphael Siegenthaler3
1Ruminant Nutrition and Emissions, Agroscope, Posieux, Switzerland.
Abstract:
Currently, there are no standardized procedures for sampling exhaled volatile organic compounds (VOCs) from dairy cows. Therefore, this study aimed to compare exhaled VOCs captured on solid-phase extraction (SPE) cartridges using five variants of three breath collection devices (face mask and GreenFeed system [C-Lock, South Dakota, US] collecting unfiltered [GreenFeedU] and filtered [GreenFeedF] air). The variants were: a tight-fitting face mask (MaskN), the MaskNwith the openings sealed using activated carbon filters (MaskF), the MaskNcovered with an over-mask ventilated with synthetic air for cow breathing (MaskV), the GreenFeedU, and the GreenFeedF. The variants were compared in two experiments (trial registration number (2023-30-FR) regarding possible VOC carryover over the samples (experiment 1) and their suitability for sampling exhaled VOC from cows (experiment 2). In both experiments, the SPE cartridges were connected to capture VOCs from collected air before GC-MS-based analysis. In experiment 1, our data showed evidence for VOC deposits and potential VOC carryover, particularly for GreenFeedU(16.3%). In exhaled breath samples from experiment 2, we detected 1217 ± 197 peaks. After subtracting the background air peaks, the exhaled VOCs consisted mostly of esters (20.9%), ketones (13.2%), and alkanes (13.0%). MaskVdetected the highest number of aldehydes, ketones, alcohols, alkanes, and alkenes, and GreenFeedUthe highest number of esters. The highest relative concentrations of most individual exhaled VOC were detected using MaskV. The tested variants, except MaskFdue to low acceptance of the animals, seemed suitable for exhaled VOC sampling, with MaskVseemed to be most suitable due to the detection of the highest VOC number and the lowest VOC carryover.
More Related Videos
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
11:02The Use of an Automated System GreenFeed to Monitor Enteric Methane and Carbon Dioxide Emissions from Ruminant Animals
Published on: September 7, 2015
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Volatilization
