Related Experiment Video
Updated: Jan 15, 2026

Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
Determinants of mask ventilation grading based on upper airway indicators: a prospective observational study
1Department of Anesthesiology, ZhongDa Hospital, Southeast University, No. 87 Dingjiaqiao, Gulou District, Nanjing, Jiangsu Province, 210009, China.
Background:
Mask ventilation is a common procedure performed in the patients with general anesthesia. Various factors that can influence airways were evaluated to determine the potential value of upper airway indicators in predicting mask ventilation grading.
Methods:
This was a secondary analysis of a prospective observational study, assessing laryngoscopy exposure risk factors by combining ultrasonically measured upper airway anatomic parameters with physical examination indicators.
Results:
A total of 1120 cases were included and were divided into the easy mask ventilation group (n = 551) and the difficult mask ventilation group (n = 569) according to the peak inspiratory pressure (PIP). There were statistically significant differences found between easy and difficult mask ventilation groups in terms of patient gender (200/351 vs. 319/250, P = 0.036), age (50.04 ± 13.41 vs. 56.81 ± 10.19, P = 0.003), history of snoring (347/168/36/0 vs. 162/271/113/23, P < 0.001), BMI (22.96 ± 2.68 vs. 25.74 ± 2.85, P < 0.001), neck circumference (36.06 ± 3.43 vs. 39.67 ± 3.10, P < 0.001), thyromental distance ratio (1.44 ± 0.17 vs. 1.37 ± 0.13.10, P = 0.012), Mallampati classification (141/354/56/0 vs. 13/420/135/1, P < 0.001), ultrasonically measured tongue thickness (5.86 ± 0.59 vs. 6.22 ± 0.47, P = 0.001), tongue root distance (3.96 ± 0.66 vs. 4.23 ± 0.69, P = 0.033), epiglottis distance (1.99 ± 0.40 vs. 2.20 ± 0.37, P = 0.033) and thyrohyosteal distance (1.69 ± 0.34 vs. 1.85 ± 0.37, P = 0.019). Multiple-factor logistic regression analysis indicated that neck circumference was an independent influencing factor, with an odds ratio of 1.37 (95% CI 1.02-1.83). At a neck circumference of 37.75 cm, the sensitivity and specificity for predicting the mask ventilation grading were 0.79 and 0.64, respectively. The predictive efficiency ROC curve AUC was 0.78 (95% CI 0.69-0.86).
Conclusions:
The neck circumference was found to be an independent predictive factor for grading mask ventilation, with an odds ratio of 1.37. The best threshold value for neck circumference prediction was 37.75 cm, with a sensitivity of 0.79 and a specificity of 0.64. And the predictive efficiency ROC curve AUC was 0.78.
Trial Registration:
chictr.org.cn ChiCTR2100053826; registered on November 30, 2021.
Related Concept Videos
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation I: Indication and Settings

