Critical fusion flicker frequency results with 1 or 2 diodes during HBOT session - observational study among

Rita Sharma1, Natalia Mankowska2, Anna Marcinkowska2

  • 1Department of Neurophysiology, Neuropsychology and Neuroinformatics, Medical University of Gdansk, Gdansk, Poland. r.sharma@gumed.edu.pl.

PubMed

Hyperbaric oxygen therapy (HBOT) is used as a treatment for acute and chronic diseases. The therapy is conducted in hyperbaric chambers. Hyperbaric medicine centers' use of multiplace chambers assures the patients' safety and comfort due to attendant's presence during each session. Among the patients and in the group of medical attendants the most common side effect of HBOT is middle ear disorder. However, inert gas narcosis occurring during compression to over 2 ATA (10 meters' of sea water equivalent) can be manifested in temporary cognitive function impairment, mostly due to nitrogen narcosis. One easily accessible and non-invasive method to assess cognitive functions is critical flicker fusion frequency test (CFFF). In our study, medical attendants were asked to perform CFFF with one and two diodes during separate HBOT sessions. No correlation was found between CFFF scores and the number of flickering lights. However, we observed a relationship between the CFFF results and the different times of day the task was performed. The fusion threshold decreased with age.

Related Concept Videos

Special considerations while measuring oxygen saturation01:19

Special considerations while measuring oxygen saturation

Assessing respiratory rate concurrently with pulse measurement is fundamental to patient care, providing valuable insights into the patient's respiratory function. The normal breathing rate for an adult usually falls within a normal range of 12 to 20 breaths per minute. Abnormal respiratory rates can signal underlying health conditions or the need for immediate intervention.
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
896
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen01:16

Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen

Oxygen therapy is a pivotal aspect of medical care, particularly for patients with respiratory ailments. Two prominent oxygen-delivering systems include the Venturi mask and the transtracheal oxygen catheter.
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
1.9K
Pulse Oximetry01:24

Pulse Oximetry

Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
1.3K