Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Graft Height and Labral Integrity as Key Determinants of Suction Seal Restoration in Hip Labral Augmentation: Findings From an Ovine Model.

Orthopaedic journal of sports medicine·2026
Same author

Rat Model of Gluteus Medius Tendon Tear: Biomechanical and Histological Effects of Autologous Fascia Lata Augmentation.

The American journal of sports medicine·2026
Same author

Relationship Between Cam Lesion Size, Its Excision, and Hip Osteoarthritis Progression: A Contralateral-Controlled Study Using Joint Space Width After Unilateral Hip Arthroscopy.

Orthopaedic journal of sports medicine·2026
Same author

Defining the postoperative alpha angle threshold for improved outcomes in posterolateral cam lesions.

Hip international : the journal of clinical and experimental research on hip pathology and therapy·2026
Same author

Clinical and Radiological Outcomes of C1-C2 Fixation: 3D-Printed Template vs. Free-Hand Technique.

Journal of clinical medicine·2026
Same author

The Preoperative Central Joint Space Holds Greater Clinical Significance in Patients Aged 35 and Older Undergoing Primary Hip Arthroscopy.

Orthopaedic journal of sports medicine·2025

Related Experiment Video

Updated: Jan 15, 2026

Ovine Lumbar Intervertebral Disc Degeneration Model Utilizing a Lateral Retroperitoneal Drill Bit Injury
07:25

Ovine Lumbar Intervertebral Disc Degeneration Model Utilizing a Lateral Retroperitoneal Drill Bit Injury

Published on: May 25, 2017

12.1K

Exploring Various Labral Reconstruction Techniques in an Ovine Hip Model: A Biomechanical Perspective.

Selahaddin Aydemir1,2, Cagri Havitcioglu3, Eren Akin1

  • 1Faculty of Medicine, Department of Orthopaedics and Traumatology, Dokuz Eylul University, Izmir, Türkiye.

The American Journal of Sports Medicine
|October 7, 2025
PubMed
Summary

Increasing graft size in hip labral reconstruction significantly improves suction seal force. Optimal graft selection and fixation techniques enhance stability, potentially improving patient outcomes and delaying osteoarthritis progression.

Keywords:
acetabular labrum allograftsbiomechanicsgraft sizelabral reconstructionovine modelsuction seal

More Related Videos

Transvaginal Mesh Insertion in the Ovine Model
10:32

Transvaginal Mesh Insertion in the Ovine Model

Published on: July 27, 2017

16.8K
Author Spotlight: A Novel 3D-Printed Titanium Implant for Minimally Invasive Treatment of Hip Dysplasia in Young Dogs
08:40

Author Spotlight: A Novel 3D-Printed Titanium Implant for Minimally Invasive Treatment of Hip Dysplasia in Young Dogs

Published on: April 19, 2024

3.7K

Related Experiment Videos

Last Updated: Jan 15, 2026

Ovine Lumbar Intervertebral Disc Degeneration Model Utilizing a Lateral Retroperitoneal Drill Bit Injury
07:25

Ovine Lumbar Intervertebral Disc Degeneration Model Utilizing a Lateral Retroperitoneal Drill Bit Injury

Published on: May 25, 2017

12.1K
Transvaginal Mesh Insertion in the Ovine Model
10:32

Transvaginal Mesh Insertion in the Ovine Model

Published on: July 27, 2017

16.8K
Author Spotlight: A Novel 3D-Printed Titanium Implant for Minimally Invasive Treatment of Hip Dysplasia in Young Dogs
08:40

Author Spotlight: A Novel 3D-Printed Titanium Implant for Minimally Invasive Treatment of Hip Dysplasia in Young Dogs

Published on: April 19, 2024

3.7K

Area of Science:

  • Orthopedic surgery
  • Biomedical engineering
  • Regenerative medicine

Background:

  • Labral reconstruction is increasingly used for hip labral deficiencies.
  • Graft materials like autografts and allografts are common.
  • Biomechanical effects of graft size, type, and fixation are not well understood.

Purpose of the Study:

  • Evaluate graft size, type, tubularization, and anchor number effects on suction seal force and stability.
  • Hypothesize larger grafts and allografts improve outcomes; tubularization has no effect.

Main Methods:

  • Controlled laboratory study using 40 ovine hip joints.
  • Randomized assignment to 5 groups: varying graft sizes (auto/allo), anchor numbers, and tubularization.
  • Measured suction seal force and distractive stability using an electromechanical system.

Main Results:

  • Larger autografts (Group 2) showed the greatest suction seal force improvement (P < .01).
  • Allografts (Group 3) performed similarly to larger autografts.
  • Increased anchors and optimal graft selection improved stability; tubularization had no effect.

Conclusions:

  • Increasing graft size enhances suction seal force in labral reconstruction, though not fully restoring native levels.
  • Optimizing graft size and fixation improves biomechanical stability.
  • Findings support strategies to enhance surgical outcomes and delay osteoarthritis progression.