Large Language Models Versus Human Readers in CAD-RADS 2.0 Categorization of Coronary CT Angiography Reports
Won-Seok Yoo1,2, Jinwoo Son1, Jin Young Kim3
1Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea.
Abstract:
This study evaluated the accuracy of large language models (LLMs) in assigning Coronary Artery Disease Reporting and Data System (CAD-RADS) 2.0 categories and modifiers based on real-world coronary CT angiography (CCTA) reports and compared their accuracy with human readers. From 2752 eligible CCTA reports generated at an academic hospital between January and September 2024, 180 were randomly selected to fit a balanced distribution of categories and modifiers. The reference standard was established by consensus between two expert cardiac radiologists with 15 and 14 years of experience, respectively. Four LLMs (O1, GPT-4o, GPT-4, GPT-3.5-turbo) and four human readers (a cardiac radiologist, a fellow, two residents) independently assigned CAD-RADS categories and modifiers for each report. For LLMs, the input prompt consisted of the report and a summary of CAD-RADS 2.0. The accuracy of evaluators in full CAD-RADS categorization was compared with O1 using McNemar tests. O1 demonstrated the highest accuracy (90.7%) in full CAD-RADS categorization, outperforming GPT-4o (73.8%), GPT-4 (59.7%), GPT-3.5-turbo (25.8%), the fellow (83.3%), and resident 1 (83.3%; all P-values ≤ 0.01). However, there was no significant difference in accuracy when compared to the cardiac radiologist (86.1%; P = 0.12) and resident 2 (89.4%; P = 0.68). Processing time per report ranged 1.34-16.61 s for LLMs, whereas human readers required 32.10-55.06 s. In the external validation dataset (n = 327) derived from two independent institutions, O1 achieved 95.7% accuracy for full CAD-RADS categorization. In conclusion, compared to human readers, O1 exhibited similar or higher accuracy and shorter processing times to produce a full CAD-RADS 2.0 categorization based on CCTA reports.
More Related Videos
06:57Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection
Published on: September 22, 2023
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies