SDM-YOLO11n: a lightweight and high-precision infusion monitoring method
Xiangyu Deng1, Wenbo Dong1, Zhecong Fan1
1College of Physics and Electronic Engineering, Northwest Normal University, Lanzhou, People's Republic of China.
Abstract:
Current infusion monitoring methods primarily rely on two technological approaches: non-visual sensor technology and visual sensor technology, for real-time monitoring of the remaining liquid volume in infusion bottles within infusion scenarios. However, non-visual sensor-based methods often suffer from complex installation procedures and are prone to external interference, while visual sensor-based methods tend to exhibit low detection accuracy in complex infusion environments involving small targets, low contrast, tilted objects, and partial occlusions, making it difficult to accurately monitor the remaining liquid. To address these challenges, we propose a high-precision and lightweight object detection algorithm-SDM-YOLO11n-based on an improved version of YOLO11n. Specifically, a lightweight Split-Parallel Convolution (SPConv) module is introduced to enhance the backbone network's spatial modeling capabilities and improve feature extraction efficiency; the traditional upsampling operation is replaced with a Dynamic Sampling (DySample) module for more adaptive feature reconstruction and multi-scale information fusion; and a Mixed Local Channel Attention (MLCA) mechanism is incorporated to strengthen attention to key regions of infusion bottles and their internal liquids, thereby further improving detection accuracy. In addition, a method based on the ratio of geometric parameters of oriented bounding boxes is proposed to precisely estimate the remaining liquid volume in infusion bottles. Experimental results show that SDM-YOLO11n improves mAP@0.5:0.95 by 0.6 percentage points compared to YOLO11n, with a model size of only 5.1 MB. The proposed algorithm achieves high-precision detection of infusion bottles and their internal liquids in complex scenarios and enables real-time monitoring of the remaining liquid volume in multiple infusion bottles.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Therapeutic Drug Monitoring: Drug Analysis Methods