Virtual contrast-enhanced maximum intensity projections from high-b-value diffusion-weighted breast MRI: a feasibility study
Related Experiment Video
Updated: Jan 6, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Andrzej Liebert1, Hannes Schreiter2, Dominique Hadler2
1Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany. andrzej.liebert@uk-erlangen.de.
Background:
Maximum intensity projections (MIPs) facilitate rapid lesion detection both for contrast-enhanced (CE) and diffusion-weighted imaging (DWI) breast magnetic resonance imaging (MRI). We evaluated the feasibility of AI-based virtual CE subtraction MIPs as a reading approach.
Materials And Methods:
This Institutional Review Board-approved retrospective study includes 540 multi-parametric breast MRI examinations (performed from 2017 to 2020), including multi-b-value DWI (50, 750, and 1,500 s/mm²). A 2D U-Net was trained using unenhanced (UnE) images as inputs to generate virtual abbreviated CE (VAbCE) subtractions. Two radiologists evaluated lesion suspicion, image quality, and artifacts for UnE, VACE, and abbreviated CE (AbCE) images. Lesion conspicuity was compared between VAbCE and AbCE MIPs.
Results:
Cancer detection rates for UE, VAbCE, and AbCE MIPs were 90.0%, 91.4%, and 94.3%, respectively. Single-slice reading demonstrated sensitivities of 88.6% (UnE), 91.4% (VAbCE), and 94.3% (AbCE). Inter-rater agreement (Cohen κ) for lesion suspicion scores was higher for VAbCE (0.53) than UnE alone (0.39) and comparable to AbCE (0.58). No significant difference in mean lesion conspicuity was observed for VACE MIPs compared to ACE (p ≥ 0.670). No significant difference could be observed for quality (p ≥ 0.108), and reading time (p = 1.000) between methods. Fewer visually significant artifacts could be observed in VAbCE than in AbCE MIPs (p ≤ 0.001).
Conclusion:
VAbCE breast MRI improved inter-rater agreement and allowed for slightly improved sensitivity compared to UnE images, while AbCE still provided the overall highest sensitivity. Further research is necessary to investigate the diagnostic potential of VAbCE breast MRI.
Relevance Statement:
VAbCE breast MRI generated by neural networks allowed the derivation of MIPs for rapid visual assessment, showing a way for screening applications.
Key Points:
Virtual abbreviated contrast-enhanced (VAbCE) MIPs provided comparable sensitivity to MIPs of unenhanced high b-value DWI and were slightly lower than AbCE MIPs. Adding VAbCE to unenhanced high b-value DWI significantly improved interrater agreement for lesion suspicion scoring. Single-slice evaluation of VAbCE MIPs provided a sensitivity comparable to unenhanced high b-value DWI MIPs.
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...