High-pressure ESI with high-temperature pre- and post-ESI heating for high-throughput analysis of hydrothermal and
Xiang Zhang1,2, Zhihua Ying1, Lee Chuin Chen2
1College of Electronics and Information, Hangzhou Dianzi University, Hangzhou, 310018, China.
Abstract:
We report a high-pressure electrospray ionization (ESI) source that incorporates a heated liquid transfer capillary, which functions as an online hydrothermal reactor, and a heated ion transport capillary for the high-throughput analysis of heating effects on analytes and on-demand thermal dissociation. Both the capillaries are resistively heated to elevated temperatures. The heated liquid transfer capillary is connected to the high-pressure ESI via a flow restrictor, and the back pressure provided by the flow restrictor, combined with the high-pressure operation of the ESI source, allows the liquid to be heated to 300 °C without boiling before being cooled to <150 °C at the ESI emitter. The generated ions and charged droplets then pass through the ion transport capillary, which can be held at 20-400 °C, before being released into the atmospheric pressure ambient for subsequent sampling by the mass spectrometer. The system is applied to the hydrothermal acceleration of Asp-selective cleavage in ubiquitin, the Pro-Pro bond-selective cleavage in bradykinin, and the formation of dipeptides of Gly-Gly and Ala-Ala from glycine and alanine, respectively. The post-ESI heating of the charged droplets and ions did not produce similar hydrothermal reactions; instead, it resulted in a gas-phase thermal dissociation that differs from the liquid-phase activation. The combination of liquid-phase and gas-phase activations can be used to tune the level of fragmentation and increase the abundance of fragments for tandem mass spectrometry, providing a potential tool for top-down proteomics.
More Related Videos
09:18Time-resolved ElectroSpray Ionization Hydrogen-deuterium Exchange Mass Spectrometry for Studying Protein Structure and Dynamics
Published on: April 17, 2017
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Chemical Ionization (CI) Mass Spectrometry
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Capillary Electrophoresis: Instrumentation
Ion-Exchange Chromatography