Oxygen Isotope Analyses of Phosphate and Organophosphorus Compounds by Electrospray Ionization Orbitrap Mass
Nora M Bernet1,2, Cleo Soldini1, Timo M O Felder3
1Eawag: Swiss Federal Institute of Aquatic Science and Technology, 8600 Dübendorf, Switzerland.
Abstract:
Orbitrap mass spectrometry with electrospray ionization (ESI-Orbitrap MS) enables 18O/16O ratio measurements in phosphate and organophosphorus compounds, which offers promising avenues for the study of metabolic, biogeochemical, and environmental processes. While the instrumental feasibility of such 18O/16O ratio measurements has been shown, the applicability of such analyses in aqueous matrices on multipurpose mass spectrometers remains unaddressed. Here, we (i) evaluated the interplay between instrument parameters and the long-term accuracy and precision of ESI-Orbitrap MS for the determination of δ18O(PO4) from H2PO4- vs PO3- fragments of phosphate, (ii) identified properties of methanolic sample solutions that are critical for accurate and precise measurements, and (iii) propose a sample purification procedure for the elimination of matrix-based interferences. In 10 measurement campaigns over two years, we observed a long-term reproducibility of δ18O(PO4) within ±2.8‰. Results of in-source fragmentation experiments of H2PO4- to PO3- show excellent agreement of δ18O and offer promising opportunities to probe for 18O/16O ratios in organophosphorus compounds. By investigating the effect of the aqueous matrix and interfering anions on 18O/16O ratio measurements, we found that a water content exceeding 50 vol % and the presence of oxyanions such as nitrate and sulfate limit measurement accuracy due to interferences of matrix constituents in the ESI source. To overcome these challenges, we evaluated selective phosphate extraction with a zirconium-based metal-organic framework (MOF) as sorbent. The resulting purification procedure allowed for successful extraction and recovery of phosphate from nitrate- and sulfate-containing aqueous solutions, resulting in methanolic phosphate samples that enabled accurate analyses of δ18O(PO4) by ESI-Orbitrap MS.
Related Concept Videos
Mass Spectrometry: Isotope Effect
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Photoluminescence: Applications
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Gas Chromatography: Types of Detectors-II