Use of polyurethane foam to prevent continuous electroencephalography-induced pressure injuries in children

Hirokazu Takeuchi1, Norimichi Higurashi1, Yurika Toga1

  • 1Department of Pediatrics, Jikei University School of Medicine Tokyo, Japan.

Journal of Wound Care
|October 10, 2025
PubMed

Insights

Preventing pressure injuries during continuous electroencephalography (CEEG) is crucial. Applying polyurethane foam pads between electrodes significantly reduced CEEG-induced pressure injuries in pediatric patients, offering a simple, cost-effective solution.

Area of Science:

  • Medical Devices
  • Patient Safety
  • Neurology

Background:

  • Continuous electroencephalography (CEEG) monitoring is vital for diagnosing neurological conditions in pediatric patients.
  • CEEG can lead to pressure injuries (PIs), particularly on the forehead and back of the head, due to prolonged electrode placement.
  • Effective strategies for preventing CEEG-induced PIs are limited, posing a risk to patient well-being.

Purpose of the Study:

  • To evaluate the efficacy of using polyurethane foam as a protective barrier between CEEG electrodes and the skin.
  • To determine if this intervention can prevent pressure injuries in pediatric patients undergoing CEEG.

Main Methods:

  • A retrospective study compared pediatric patients undergoing CEEG with and without polyurethane foam padding.
  • The polyurethane group had foam padding placed on the forehead and/or back of the head.
  • The primary outcome measured was the pressure injury prevention rate in the polyurethane group.

Main Results:

  • The study included 77 patients in the non-polyurethane group and 65 in the polyurethane group.
  • The incidence of PIs was significantly lower in the polyurethane group (1.5%) compared to the non-polyurethane group (6.5%).
  • The PI prevention rate in the polyurethane group was 77%.

Conclusions:

  • Placing polyurethane foam during CEEG effectively prevents CEEG-induced pressure injuries in pediatric patients.
  • This simple and inexpensive method is easily implementable in various healthcare settings.
  • The findings suggest a valuable, low-cost intervention for enhancing patient safety during CEEG monitoring.
Abstract