Robustness of a convolutional neural network trained on dermoscopic images and challenged with close-up images
Anastasia Sophie Vollmer1, Julia Katharina Winkler1, Katharina Susanne Kommoss1
1Department of Dermatology, University medical Center Heidelberg, Heidelberg, Germany.
Background And Objectives:
Deep learning-convolutional neural networks (DL-CNNs) have demonstrated high diagnostic accuracy within the domain of dermoscopy. However, many clinical settings lack dermoscopic devices, requiring reliance on close-up images. This study evaluates the robustness of a DL-CNN trained on dermoscopic images when challenged with close-up images.
Methods:
In this cross-sectional study, the DL-CNN Moleanalyzer pro, trained on 129,487 dermoscopic images, was tested on 350 skin lesions, each imaged both clinically and dermoscopically. Histopathology (89.4%) or expert consensus with a two-year follow-up (10.6%) served as the reference standard. Primary outcomes included sensitivity, specificity, and the receiver operating characteristic-area under the curve (ROC-AUC).
Results:
For dermoscopic images, the DL-CNN achieved a sensitivity of 88.2% (95% CI: 82.9%-92.0%), specificity of 69.0% (61.4%-75.8%), and a ROC-AUC of 0.866 (0.860-0.873). For close-up images of the same lesions, sensitivity decreased to 60.5% (53.5%-67.1%, p < 0.001), while specificity increased to 79.4% (72.3%-85.0%, p = 0.027). The ROC-AUC for close-up images was 0.780 (0.772-0.790, p = 0.003).
Conclusions:
Our findings highlight the diagnostic limitations of applying DL-CNNs trained on dermoscopic images to close-up images, with reduced sensitivity but increased specificity. The results emphasize the need to improve cross-domain adaptability. Fine-tuning of DL-CNNs on clinical images may enhance real-world diagnostic accuracy.
Related Concept Videos
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Convolution Properties II
The width property indicates that if the durations of input signals are T1 and T2, then the width of the output response equals the sum of both durations, irrespective of the shapes of the two functions. For instance, convolving two rectangular pulses with durations of 2 seconds and 1 second results in a function with a width of 3 seconds.
The area property asserts that the area under the...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...