Quantitative evaluation of entrance skin dose from kV imaging in respiratory motion-tracking radiotherapy
Yosuke Miyauchi1, Shogo Tsunemine2, Tetsuya Tomida2
1Department of Radiation and Proton Therapy Office, Shizuoka Cancer Center, Shizuoka, 411-8777, Japan. y.miyauchi@scchr.jp.
Abstract:
Although some studies have reported the radiation doses associated with kilovoltage (kV) X-ray imaging in motion-tracking radiotherapy using Radixact Synchrony, detailed assessments of skin doses that reflect the actual imaging frequency and patient positioning remain insufficient. This study aimed to estimate the entrance skin dose (ESD) associated with frequent kV image acquisition, evaluate the radiation dose in past patients at our hospital, and identify the contribution of imaging dose relative to the prescription dose and dose constraints. For each protocol available on the Radixact Synchrony system, the half-value layer, X-ray tube voltage, and air kerma at the kV imaging isocenter were measured using a semiconductor detector (RaySafe X2, Unfors RaySafe AB, Sweden). The ESD associated with the kV image acquisition was estimated based on the number of kV image acquisitions during tracking and corresponding imaging angles from 109 patients who underwent motion-tracking radiotherapy. The total number of imaging exposures throughout the treatment period averaged 1230 per patient, with a maximum of 3750. The cumulative ESD per acquisition angle averaged 69.1 mGy, with a maximum of 367.2 mGy. Furthermore, by considering the overlap of imaging angles and the influence of transmitted X-rays, the estimated maximum skin dose was 951.9 mGy. In this case, the maximum skin dose in the treatment plan was 47.9 Gy, and so the imaging dose corresponded to approximately 2% of the prescribed skin dose. Our findings indicate that the contribution of the imaging dose to the treatment dose is sufficiently low.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET