Related Experiment Video
Updated: Jan 6, 2026

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Rapid and sensitive detection of polycyclic aromatic hydrocarbons using electrochemically assisted derivatization
Heng-Yu Xu1,2, Zhi-Cai Jiang1, Cheng-Fei Lu1
1China Tobacco Zhejiang Industrial Co. Ltd, Ningbo, 315502, P. R. China.
Abstract:
Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous toxic pollutants that pose significant risks to human health. However, because of their intrinsic non-polar properties, only moderate detection sensitivity can be achieved in the mass spectrometric detection of PAHs. In this work, we presented a novel electrochemically assisted derivatization nano-electrospray ionization mass spectrometry (ECAD-nESI-MS) method to permit the rapid and ultrasensitive analysis of PAHs in complicated samples. In ECAD-nESI-MS, the in situ electrochemical derivatization of PAHs with pyridine and the electrospray ionization are simultaneously activated by applying a high voltage onto the Pt electrode. Notably, the derivatization takes advantage of the inherent electrochemical aspect of electrospray ionization, that is, the electrooxidation of substrates in the positive-ion mode, thus requiring no extra electrochemical cell and potentiostat. Through the electrochemical derivatization of PAHs into the corresponding pyridinium ions, the ECAD-nESI-MS method achieved remarkably improved detection sensitivity, where the limit of detection (LOD) is 3~10 times lower than the state-of-the-art atmospheric pressure chemical ionization mass spectrometry (APCI-MS) and gas chromatography mass spectrometry (GC-MS). With advantages in low detection limit, wide linear range, fast analysis speed (< 3 min per sample), and low sample consumption, we anticipate the wide application of the ECAD-nESI-MS method in the rapid and sensitive analysis of PAHs and their analogues.
More Related Videos
11:14Rapid High-throughput Species Identification of Botanical Material Using Direct Analysis in Real Time High Resolution Mass Spectrometry
Published on: October 2, 2016
11:44Using Cyclic Voltammetry, UV-Vis-NIR, and EPR Spectroelectrochemistry to Analyze Organic Compounds
Published on: October 18, 2018
Related Concept Videos
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Tandem Mass Spectrometry
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...