Related Experiment Video For Dual-layer spectral detector computed tomography (DLCT)
Updated: Jan 15, 2026

Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Dual-layer spectral detector computed tomography in distinguishing between bland and neoplastic portal vein
Lin Zhang1,2, Tianying Zheng1, Mao Su1
1Department of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Background:
Differentiating bland from neoplastic portal vein thrombosis (PVT) is crucial for staging and treatment decisions in patients with suspected or confirmed liver malignancies. This study aimed to assess the diagnostic efficacy of the quantitative parameters of dual-layer spectral detector computed tomography (DLCT) in distinguishing between bland and neoplastic PVT.
Methods:
This single-center prospective study included consecutive patients with identifiable PVT who underwent contrast-enhanced liver DLCT between April 2022 and August 2023. The reference standard was established based on imaging, patient history, and follow-up data. Quantitative parameters, including computed tomography (CT) attenuation values from conventional and virtual monoenergetic (40-90 keV) images, iodine density, effective atomic number (Zeff), and arterial enhancement fraction (AEF), were documented. Interobserver agreement was assessed via the intraclass correlation coefficient (ICC). A combined score integrating DLCT quantitative parameters was developed, and diagnostic performance was evaluated according to the area under the receiver operating characteristic (ROC) curve (AUC), sensitivity, and specificity.
Results:
A total of 81 patients (median age 54 years; 64 males) were enrolled, including 31 patients with bland PVT and 50 with neoplastic PVT. Baseline characteristics showed significant differences between the bland PVT and neoplastic PVT groups, including in α-fetoprotein (AFP) level (median 3.3 vs. 932.0 ng/mL, P<0.001), aspartate aminotransferase (AST) level (median 40.0 vs. 68.5 U/L, P=0.004), and PVT diameter (mean 13.6 vs. 16.5 mm, P=0.02). The quantitative DLCT parameters were significantly different between the bland and neoplastic groups (all P values ≤0.001). Interobserver agreement was good to excellent (ICC 0.796-0.973). Quantitative parameters from the arterial phase, as compared to those from the portal venous phase, exhibited higher diagnostic AUC values and specificity, but lower sensitivity for neoplastic PVT. The CT attenuation values of arterial-phase 40-keV virtual monoenergetic images achieved the highest AUC of 0.938 [95% confidence interval (CI): 0.862-0.980], with a sensitivity of 84.0% and a specificity of 96.8%. The AEF also showed high diagnostic performance, with an AUC of 0.930 (95% CI: 0.851-0.975), a sensitivity of 90.0%, and a specificity of 93.6%. The combined score derived from the arterial-phase DLCT quantitative parameters and AEF achieved the highest AUC of 0.979 (95% CI: 0.919-0.998) for diagnosing neoplastic PVT, with a sensitivity and specificity of 94.0% and 100.0%, respectively.
Conclusions:
DLCT quantitative parameters effectively distinguished between bland and neoplastic PVT. The combined score derived from quantitative DLCT parameters demonstrated superior diagnostic performance, potentially aiding in accurate staging and treatment decisions for patients with suspected or confirmed liver malignancies. Further large-scale multicenter studies are needed to confirm these findings.
More Related Videos
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT

