Related Experiment Video
Updated: Jan 15, 2026

Simulation of Early Earth Hydrothermal Chimneys in a Thermal Gradient Environment
Published on: February 27, 2021
Hydrothermal vent temperatures track magmatic inflation and forecast eruptions at the East Pacific Rise, 9°50'N
Thibaut Barreyre1,2, Jean-Arthur Olive3, Daniel J Fornari2
1Geo-Ocean, Univ Brest, CNRS, Ifremer, UMR6538, Plouzané F-29280, France.
Abstract:
Hydrothermal vent temperatures fluctuate in response to transient magmatic and tectonic activity at the axis of mid-ocean ridges (MORs) and modulate energy fluxes from the deep Earth to the ocean. Such fluctuations have thus far only been documented on time scales of minutes to years, because of the scarcity of long, continuous observations. Here, we assemble a ~35-year-long time series of exit fluid temperatures from five hydrothermal vents on the East Pacific Rise axis, between 9°46'-51'N. This dataset reveals a steady increase in maximum venting temperatures atop the central part of the axial magma lens (AML), from ~350 °C to ~390 °C between the 1991-92 and 2005-06 eruptions. Temperatures decreased back to ~350 °C shortly after the 2005-06 eruption and have been rising ever since. We interpret the temperature increase as a result of a steady decrease in upflow zone permeability caused by the steady inflation of the AML compressing the oceanic upper crust. Using laboratory-determined pressure-permeability relations, we estimate crustal pressurization rates of 0.38 MPa/y (1992-2005) and 0.33 MPa/y (post-2006), consistent with geodetic observations from 2009-2011. Decadal fluctuations in hydrothermal vent temperatures likely mimic the rate of AML pressurization, yielding valuable new constraints on the dynamics of magmatic replenishment and eruptions at MORs. Notably, this temperature time series underpinned our forecast of the April 2025 eruption at the study site.
Related Concept Videos
Isothermal Processes
An ideal gas can also undergo isothermal expansion or compression.
For example, consider 1 mole of an ideal gas inside an isolated cylinder at initial volume V...
Gas Thermometers and the Kelvin Scale
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Heat Flow and Specific Heat
Thermometers and Temperature Scales
As many physical properties depend on temperature, the variety of thermometers is...
Freezing Point Depression and Boiling Point Elevation
The boiling point of a liquid is the temperature at which its vapor pressure is equal to ambient atmospheric pressure. Since the vapor pressure of a solution is lowered due to the presence of nonvolatile solutes, it stands to reason that the solution’s boiling point will subsequently be increased. Vapor pressure increases with temperature, and so a solution will require a higher temperature than will pure solvent to achieve any given vapor pressure, including one...

