State-of-the-Art Review of Current Technology in Pressure Injury Early Detection
Yi-Ting Tzen1, Barbara Delmore2, Kath M Bogie3
1Department of Applied Clinical Research and Department of Physical Medicine and Rehabilitation, UT Southwestern Medical Center, Dallas, TX.
Advances in Skin & Wound Care
|October 14, 2025
Summary
Several devices show promise for early pressure injury (PI) detection, particularly in individuals with darker skin tones. These technologies can augment, but not replace, standard skin assessments for high-risk patients.
Area of Science:
- Biomedical Engineering
- Clinical Technology
- Dermatology
Background:
- Pressure injuries (PIs) represent a significant healthcare challenge.
- Early detection of PIs is crucial for effective prevention and treatment.
- Current standard assessments rely on visual inspection and palpation, which may have limitations.
Purpose of the Study:
- To review available devices for early pressure injury detection.
- To summarize challenges and opportunities for clinical implementation of these devices.
- To propose evaluation standards for different device categories.
Main Methods:
- Systematic review of PubMed and US Food and Drug Administration (FDA) databases.
- Inclusion of English, peer-reviewed, full-text articles.
- Exclusion of opinion statements, non-empirical data, or unrelated studies.
- Data extraction included measurement mechanisms, output, FDA classification, and clinical use data.
Main Results:
- Four clinical devices identified: ultrasound, infrared thermography, subepidermal moisture assessment, and near-infrared spectroscopy.
- Three research devices identified: laser Doppler flowmetry, laser speckle contrast imaging, and colorimetry.
- Devices measure non-visual signs of PI like inflammation, edema, ischemia, and hypoxia (except colorimetry).
Conclusions:
- Clinical devices show potential for early PI identification, especially in individuals with dark skin tones.
- No reimbursement is currently available for PI early detection technologies.
- Validated devices should augment, not replace, standard visual and palpation assessments for high-risk patients.
Related Concept Videos
Equipments Used To Measure Blood Pressure
3.1K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
3.1K
Assessing Blood pressure using a doppler ultrasound
2.4K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
2.4K