MIMOSA: Multi-Parametric Imaging Using Multiple-Echoes With Optimized Simultaneous Acquisition for Highly-Efficient
Yuting Chen1,2,3, Yohan Jun2,3, Amir Heydari4
1State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, China.
Purpose:
To develop a new sequence, MIMOSA, for highly efficient T1, T2, T2*, proton density (PD), and source separation quantitative susceptibility mapping (QSM).
Methods:
MIMOSA was developed based on 3D quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) by combining 3D turbo Fast Low Angle Shot (FLASH) and multi-echo gradient echo acquisition modules with a spiral-like Cartesian trajectory to facilitate highly efficient acquisition. Simulations were performed to optimize the sequence. A multi-contrast/-slice zero-shot self-supervised learning algorithm was employed for reconstruction. The accuracy of quantitative mapping was assessed by comparing MIMOSA with 3D-QALAS and reference techniques in both ISMRM/NIST phantom and in vivo experiments. MIMOSA's acceleration capability was assessed at R = 3.3, 6.5, and 11.8 in in vivo experiments, with repeatability assessed through scan-rescan studies. Beyond the 3 T experiments, mesoscale quantitative mapping was performed at 750 μm isotropic resolution at 7 T.
Results:
Simulations demonstrated that MIMOSA achieved improved parameter estimation accuracy compared to 3D-QALAS. Phantom experiments indicated that MIMOSA exhibited better agreement with the reference techniques than 3D-QALAS. In vivo experiments demonstrated that an acceleration factor of up to R = 11.8-fold can be achieved while preserving parameter estimation accuracy, with intra-class correlation coefficients of 0.998 (T1), 0.973 (T2), 0.947 (T2*), 0.992 (QSM), 0.987 (paramagnetic susceptibility), and 0.977 (diamagnetic susceptibility) in scan-rescan studies. Whole-brain T1, T2, T2*, PD, and source separation QSM were obtained with 1 mm isotropic resolution in 3 min at 3 T and 750 μm isotropic resolution in 13 min at 7 T.
Conclusion:
MIMOSA demonstrated potential for highly efficient and repeatable multi-parametric mapping.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...