Related Experiment Video
Updated: Jan 15, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Functional Outcomes of Intra-articular Distal Radius Fractures: Single-Incision Three-Column Fixation Using Volar
Sunil Kumar1, Harish Kumar1, Pradeep K Gupta2
1Orthopaedics and Traumatology, Uttar Pradesh University of Medical Sciences, Etawah, IND.
Background:
Distal radius fractures are common, accounting for 17% of all fractures and 75% of forearm fractures. Their age distribution is bimodal, affecting younger individuals with high-energy trauma and older adults with osteoporotic bones. Efficient management is essential to prevent long-term complications such as malunion and chronic discomfort. This study aims to evaluate the clinical and functional outcomes of intra-articular distal radius fractures treated with a modified surgical procedure using a 2.7-mm locking volar plate and K-wires for three-column fixation via a single volar approach.
Methods:
This prospective interventional study was conducted at a tertiary care institute from January 2019 to August 2020. Patients with closed or open (Gustilo Anderson Type I) intra-articular distal radius fractures classified as AO Types B and C were included. Exclusion criteria were complex fractures (Type II or III), pathological fractures, or significant comorbidities. Thirty-five patients underwent treatment with volar plating, with or without K-wire fixation, and were subsequently monitored for clinical and functional outcomes using QuickDASH ratings and range of motion assessments. Radiographic evaluations were performed to assess fracture alignment and healing.
Results:
The study included 24 males and 11 females, with a mean age of 35.2 years. QuickDASH scores improved significantly, from 67.8 at one month to 8.07 at six months (p < 0.00001). Wrist range of motion also showed marked improvement across all parameters. Radiographic findings remained stable during follow-up, with no changes in volar tilt, radial inclination, or ulnar variance. Complications were minimal, with three patients developing wrist stiffness and one patient experiencing a postoperative infection.
Conclusion:
The modified surgical technique using a 2.7-mm locking volar plate and K-wires for three-column fixation offers efficient stabilization and functional recovery in intra-articular distal radius fractures. This method offers significant improvements in wrist function while maintaining consistent radiographic outcomes, supporting its use in the management of complex fractures.