Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Combined mechanical ventilatory and mechanical circulatory support aids pulmonary vascular state in cardiogenic shock
Kimberly K Lamberti1, Elazer R Edelman2,3, Steven P Keller4
1Institute for Medical Engineering and Science, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA, 02139, USA. kkl@mit.edu.
Background:
Percutaneous ventricular assist devices (pVADs) support patients in circulatory failure and increasingly concomitant respiratory failure. The presence of co-existent lung disease creates a management challenge due to cardiopulmonary interactions, especially when there is simultaneous mechanical ventilation and mechanical circulatory support. Enhanced understanding of the combined effects of these devices is necessary to better inform care for circulatory failure patients.
Methods:
A porcine model of titratable acute cardiogenic shock was used to quantify the effect of pVAD support on cardiac loading states in five intubated animals with positive pressure ventilation and varied intrathoracic pressure. Cardiovascular hemodynamics were assessed across positive end-expiratory pressure (PEEP) ramps in animals in health, health with pVAD, and pVAD-supported cardiogenic shock induced via coronary microembolization.
Results:
This study employed invasive physiological metrics and assessment of right and left ventricular press-volume loops to recreate classic Frank-Starling curves. Increased intrathoracic pressure altered transmural pressure in the ventricles and the pulmonary vasculature and resulted in decreased venous return and stroke volume while increasing end-diastolic pressure consistent with decreased ventricular compliance. In pVAD-supported cardiogenic shock, elevated PEEP enhanced left ventricular output and increased pulmonary vascular compliance in several animals, contrary to traditional decrements observed with elevated PEEP. The right ventricular functional response aligned with these varied responses in pulmonary vascular state.
Conclusions:
These results demonstrate that combined used of cardiopulmonary support devices in cardiogenic shock can create variable responses compared to classic physiological understanding. In pVAD-supported cardiogenic shock, an increase in ventilatory PEEP increased unloading from the heart and improved right ventricular function, counter to traditional findings. This demonstrates that combined use of these technologies could be leveraged to optimize a patient's volume status in complex shock and provides promise for management of patients with cardiopulmonary failure requiring simultaneous use of mechanical circulatory support and mechanical ventilation.
More Related Videos
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Cardiomyopathy II: Dilated Cardiomyopathy
Cardiomyopathy VII: Pre and Post Operative Nursing Management