Related Experiment Video
Updated: Jan 15, 2026

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Development and Pilot Testing of Hypertension Management Support With EHR-Integrated Telemonitoring and Proactive
Stephen D Persell1,2, Yaw Peprah1, Ji Young Lee1
1Division of General Internal Medicine, Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.
Background:
Automated patient messages based on home blood pressure (BP) may help overcome clinician and patient inertia in hypertension treatment.
Methods:
We designed and piloted an automated messaging system based on remote patient monitoring (RPM) results delivered through patients' electronic health record portal. Messages included reminders to monitor, what to do if BP is above or below goal, and positive feedback when goal BP is achieved; these were triggered via a deterministic algorithm based on reported home BPs. Seven clinicians agreed to participate in this pilot study. Patients with the most recent two office BPs ≥140/90 mmHg were eligible. Outcomes assessed after 9 months included change in home SBP, net change in antihypertensive medication, and number of automated messages. Subgroup analysis was conducted by baseline home BP.
Results:
Of 285 eligible patients, 70 (25%) enrolled. Baseline mean (SD) office systolic/diastolic BP was 148(18)/81(12) mmHg. By 9 months, participants had received a mean (range) of 13 (5-44) messages and viewed 85%. Among 64 patients completing the 9-month study visit, the baseline home BP was 142(17)/84(15) mmHg, 9-month change in home SBP was -9.4 mmHg (95% CI: -1.3, -14.7). Among 13 patients with controlled baseline home BP (<130/80 mmHg), SBP change was +2.7 mmHg (-4.8, +12.3). Among 51 patients with uncontrolled baseline home BP, SBP change was -12.5 mmHg (-5.2, -16.8); 51% had antihypertensive pharmacotherapy increased.
Conclusions:
Delivering automated feedback based on RPM BP results through a commercial electronic health record was feasible. Participants with sustained hypertension had large BP declines.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Hypertension V: Nursing Management
Holter Monitor: 24-Hour Monitoring
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Hypertension III: Clinical Manifestations and Diagnostic Studies
Pre-Procedural Guidelines for Assessing Blood Pressure