Related Experiment Video
Updated: Jan 15, 2026

Contrast Enhanced Vessel Imaging using MicroCT
Published on: January 27, 2011
Development and evaluation of a novel organ-specific biomechanics-guided contrast-enhanced CT volume synthesis model
Shilun Du1, Mengruo Shen1, Yibiao Liu1
1State Key Laboratory of Fluid Power & Mechatronic Systems, Zhejiang University, Hangzhou, Zhejiang, People's Republic of China.
Abstract:
Objective.Contrast-EnhancedComputedTomography (CECT) is a critical medical imaging modality, yet acquiring and annotating such datasets remains time-consuming. Generative models show potential in augmenting datasets, but existing methods mainly focus on single-organ CECT with small deformations and struggle to generate diverse data with large deformations.We aim to propose a novel biomechanics-guided CECT volume synthesizing model for generating deformed CECT volumes, and evaluate the effectiveness of deformation-augmented CECT datasets for downstream tasks.Approach. First, we develop a biomechanics-guided deformable CECT volume synthesizing framework using deformation as input to aConditionalGenerativeAdversarialNetworks, and using sequential deformations to further generate temporally consistent deformed CECT volumes. Second, we propose a module for transition region generation and contrast adjustment in CECT. Third, we trained the deformable synthesis model on liver and kidney CECT datasets and used it for dataset augmentation. The synthesized CECT volumes fidelity was verified through qualitative and quantitative tests. The augmented dataset's effectiveness was evaluated for downstream tasks, including segmentation and multi-organ deformable image registration.Main Results. For image fidelity, the meanDiceSimilarityCoefficient (DSC) andStructuralSimilarityIndexMeasure for the synthesized CECT volumes continuity are 0.838 and 0.988, higher than the real CT volumes. Our method outperforms existing approaches in comparative experiments. The specificity and sensitivity in radiologist Turing test are 47.5%and 48.0%. Comparison between deformedex vivoporcine liver CT and synthesized CECT shows the model generates realistic deformed CT. In segmentation, model on augmented datasets achieves a mean mAP@50 scores of 0.641, outperforming 0.399 without augmentation. In deformable image registration, DSC improves by 7%as the augmented training frames increases.Significance. The proposed model can synthesize deformable CECT volumes, augmenting dataset diversity and size. The synthesized CECT volumes reveal good volume continuity and perceptual similarity to real CECT. The augmented datasets can improve the performance for downstream tasks.
More Related Videos
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
09:57Development and Evaluation of 3D-Printed Cardiovascular Phantoms for Interventional Planning and Training
Published on: January 18, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT