Arc Fault Detection for Photovoltaic Systems Using Independent Component Analysis Technique and Dynamic Time-Warping
Jiazi Xu1, Shuo Ding2, Guoli Li2
1School of Electronic and Information Engineering, Anhui University, Hefei 230601, China.
Sensors (Basel, Switzerland)
|October 16, 2025
Summary
This study introduces a novel arc fault detection method for photovoltaic systems using independent component analysis (ICA). The technique leverages global signal features for improved accuracy and robustness in noisy environments.
Area of Science:
- Electrical Engineering
- Renewable Energy Systems
- Signal Processing
Background:
- Arc faults in photovoltaic (PV) systems pose significant fire and explosion risks.
- Existing detection methods often rely on local arc features, leading to failures in noisy conditions.
- A global feature-based approach is needed for reliable PV arc fault detection.
Purpose of the Study:
- To propose a novel arc fault detection method for PV systems.
- To utilize global signal characteristics for enhanced detection accuracy and robustness.
- To address the limitations of traditional local feature-based methods.
Main Methods:
- Independent Component Analysis (ICA) to decompose DC current signals.
- Characterizing arc faults based on the independence of decomposed signals.
- Dynamic Time Warping (DTW) to quantify signal independence for detection.
- End-to-end arc fault detection system implementation.
Main Results:
- PV DC currents with arc faults decompose into two independent components via ICA.
- Normal PV DC currents do not exhibit this two-component independence.
- The proposed ICA-based method demonstrates superior detection accuracy.
- Enhanced robustness against environmental disturbances compared to traditional methods.
Conclusions:
- The proposed method effectively detects arc faults by analyzing signal independence.
- Global feature analysis using ICA offers a significant improvement over local feature methods.
- This approach enhances the safety and reliability of photovoltaic systems.
Keywords:
arc faultsdynamic time warpingglobal featureindependent component analysisphotovoltaic systemMore Related Videos
Related Concept Videos
Power System Three-Phase Short Circuits
519
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
519
Three-Phase Short Circuit—Unloaded Synchronous Machine
663
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
663
Fault Types
399
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
399
Fast Decoupled and DC Powerflow
725
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
725
Bus Impedance Matrix
499
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
499
Reclosers and Fuses
452
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
452