Related Experiment Video
Updated: Jan 15, 2026

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection
Published on: December 15, 2015
Multicapillary columns with diffusional bridging: the combined polydispersity and scatter problem
Bram Huygens1, François Parmentier2, Gert Desmet1
1Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium.
Abstract:
The present study expands upon the modelling of band broadening in multicapillary columns with diffusional bridging, which have been proposed as an alternative to more conventional column designs. The plate height of these columns, consisting of a bundle of cylindrical capillaries, is already known to be affected by the variance of the capillaries' diameters but may furthermore be affected by the spatial distribution of the capillaries across the cross-section. The combined effect of these 'polydispersity' and 'scatter' problems is modelled here by means of mathematical analysis and numerical computations, building upon the framework of Taylor-Aris dispersion and assuming the capillaries are randomly distributed across the cross-section. Both the steady-state and the transient regime of dispersion are evaluated. The acquired data allow to establish equations relating the plate height to the geometrical parameters of the column (including the external porosity and the number of capillaries) as well as the physicochemical parameters of the analyte (including the diffusion coefficient and the retention factor). The term originating from polydispersity, which has been the subject of previous studies, is found to be exceeded by the term originating from scatter, which has not yet received the same attention. The best approach to alleviate the effect of disorder is found to be maximising the external porosity of the multicapillary columns, by adding more capillaries within a given cross-section.
Related Concept Videos
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Capillary Electrophoresis: Instrumentation
Principles Of Column Chromatography
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...