Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Diffusion on Chromatography Columns01:07

Diffusion on Chromatography Columns

1.2K
In column chromatography, when an analyte is introduced as a narrow band at the top of the column, the solutes begin to separate and broaden, developing a Gaussian profile. This broadening occurs due to various factors, such as longitudinal diffusion.
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
1.2K
Column Efficiency: Rate Theory01:12

Column Efficiency: Rate Theory

880
The rate theory of chromatography provides quantitative insight into the shapes and widths of elution bands. These bands are based on the random-walk mechanism governing molecular migration within a column. The Gaussian profile of chromatographic bands arises from the cumulative effect of random molecular motions as they progress through the column.
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
880
Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

979
Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
979
Principles Of Column Chromatography01:13

Principles Of Column Chromatography

8.5K
The chromatography technique was first invented in 1901 by Michael S. Tswett, a Russian botanist, to separate plant pigments using organic solvents. Further, in 1941, Archer John Porter Martin and R. L. M. Synge modified the technique by packing silica gel into a column. A mixture of amino acids was then separated on the packed column using chloroform and water mixture as the mobile phase. This was the first report on column chromatography. At present, column chromatography is a widely used...
8.5K
Chromatographic Resolution01:15

Chromatographic Resolution

2.0K
In chromatography, a solute moves through a chromatographic column and tends to spread, forming a Gaussian-shaped band. The longer the solute spends in the column, the broader the band becomes. The broadening can lead to overlaps within the column, affecting separation effectiveness.
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
2.0K
Optimizing Chromatographic Separations01:15

Optimizing Chromatographic Separations

876
Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
876

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Uncertainty-driven model-based search methods for method development in liquid chromatography.

Journal of chromatography. A·2026
Same author

Automated micropillar array design with Bayesian optimization and computational fluid dynamics.

Journal of chromatography. A·2026
Same author

Computational study of the mass transfer effects in metal-organic framework columns for liquid chromatography.

Journal of chromatography. A·2026
Same author

Revisiting the definition and measurement of total accessible and hold-up volumes in liquid chromatography: Current understanding and advances.

Journal of chromatography. A·2026
Same author

SERS Substrate Fabrication via Rapid Triboelectrification-Driven Self-Assembly of Close-Packed Colloidal Monolayers.

Small methods·2026
Same author

Kinetic plot method for the optimal column and instrument design for high speed chiral SFC applications.

Journal of chromatography. A·2026

Related Experiment Video

Updated: Jan 15, 2026

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection
08:01

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection

Published on: December 15, 2015

7.9K

Multicapillary columns with diffusional bridging: the combined polydispersity and scatter problem.

Bram Huygens1, François Parmentier2, Gert Desmet1

  • 1Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium.

Journal of Chromatography. A
|October 16, 2025
PubMed
Summary
This summary is machine-generated.

Disorder in multicapillary columns significantly impacts band broadening. Maximizing external porosity by increasing capillary numbers is key to improving chromatographic separation performance.

Keywords:
Effective medium theoryFourier analysisMulticapillary columnPlate heightPorous layer open tubular column

More Related Videos

Curtain Flow Column: Optimization of Efficiency and Sensitivity
06:44

Curtain Flow Column: Optimization of Efficiency and Sensitivity

Published on: June 12, 2016

6.9K
Assembly and Characterization of Polyelectrolyte Complex Micelles
08:44

Assembly and Characterization of Polyelectrolyte Complex Micelles

Published on: March 2, 2020

11.5K

Related Experiment Videos

Last Updated: Jan 15, 2026

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection
08:01

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection

Published on: December 15, 2015

7.9K
Curtain Flow Column: Optimization of Efficiency and Sensitivity
06:44

Curtain Flow Column: Optimization of Efficiency and Sensitivity

Published on: June 12, 2016

6.9K
Assembly and Characterization of Polyelectrolyte Complex Micelles
08:44

Assembly and Characterization of Polyelectrolyte Complex Micelles

Published on: March 2, 2020

11.5K

Area of Science:

  • Analytical Chemistry
  • Chromatography

Background:

  • Multicapillary columns offer an alternative to conventional designs.
  • Band broadening in these columns is influenced by capillary diameter variance and spatial distribution.

Purpose of the Study:

  • To model the combined effects of capillary diameter polydispersity and spatial scatter on band broadening.
  • To develop equations relating plate height to column geometry and analyte properties.

Main Methods:

  • Mathematical analysis and numerical computations based on Taylor-Aris dispersion theory.
  • Evaluation of both steady-state and transient dispersion regimes.

Main Results:

  • The 'scatter' effect on plate height is more significant than the 'polydispersity' effect.
  • Established relationships between plate height, column parameters (porosity, capillary number), and analyte properties (diffusion coefficient, retention factor).

Conclusions:

  • Capillary spatial distribution ('scatter') is a critical factor in multicapillary column band broadening.
  • Maximizing external porosity by increasing capillary density is the most effective strategy to mitigate disorder effects and enhance separation efficiency.