Related Experiment Video
Updated: Jan 14, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Procedural Risk Associated With Anomalous Coronary Artery Supply During Aortic Valve Replacement
Neha Chandna1, Asmita Itani2, Anjali Gaalla1
1Medicine, Victoria Heart and Vascular Center, Victoria, USA.
None:
Aortic stenosis (AS) is a common valvular heart disease in the elderly population. Transcatheter aortic valve replacement (TAVR) is a preferred modality for severe symptomatic AS management in elderly patients with high surgical risk. However, unusual coronary artery supply with anatomical variations may increase the procedural risk in TAVR, making surgical aortic valve replacement (SAVR) a suitable modality. This article presents a case of a 77-year-old male with severe symptomatic AS with an uncommon coronary anomaly where all three major coronary arteries originate from the right coronary sinus, posing a high risk for coronary obstruction during TAVR. The SAVR procedure was performed successfully, allowing for direct visualization and protection of the anomalous coronary ostia. This case emphasizes the crucial role of pre-procedural catheterization and surgical planning in patients with atypical coronary artery supply.
More Related Videos
Related Concept Videos
Aneurysm IV: Nursing Management
Aneurysm III: Interprofessional Care
Aortic Regurgitation I: Introduction
Aortic Regurgitation III: Medical Management
Cardiac Catheterization II: Right Heart Catheterization