Related Experiment Video
Updated: Jan 6, 2026

Fabrication and Characterization of a Conformal Skin-like Electronic System for Quantitative, Cutaneous Wound Management
Published on: September 2, 2015
Validation of the iButton and Flex sensors for measuring skin temperature
David Bandiera1,2, Jean de Bardonnèche2, Philippe Janry3
1Department of Movement, Human and Health Sciences, University of Rome Foro Italico, Rome, Italy.
Purpose:
Skin temperature is a critical component of athletes' heat strain during exercise in the heat. This study evaluated the innovative Flex sensor (BodyCap, Caen, France), allowing real-time measurements, against a data logger (iButton hygrochron DS1923, Analog Devices, Wilmington, USA), commonly used in sports science.
Methods:
In a first study, the accuracies of iButton faces as well as the Flex sensor were tested on a constant-temperature Peltier module affixed to a brass plate. In a second study, concurrent skin temperature measurements were conducted with both sensors on eight participants cycling in hot conditions.
Results:
Both faces of the iButton underestimated plate temperature, with the base (ME = mean error: 0.59 ± 0.25 °C at 30 °C, 1.62 ± 0.48 °C at 40 °C) being significantly more accurate than the top (ME: 1.14 ± 0.26 °C at 30 °C, 3.02 ± 0.71 °C at 40 °C, p < 0.001). The rate of temperature increase of the base was also higher than the top at 30 °C (1.97 ± 0.16 °C/min vs 1.49 ± 0.15 °C/min) and 40 °C (4.41 ± 0.46 °C/min vs 3.14 ± 0.16 °C/min, both p < 0.001). The Flex sensor underestimated plate temperature (ME: 1.31 ± 0.32 °C at 30 °C, 3.00 ± 0.84 °C at 40 °C), showing larger errors than the iButton base (p < 0.001). During exercise, the Flex sensor (36.91 ± 1.19 °C) measured higher skin temperature compared to the iButton (36.50 ± 1.15 °C), with an ME of -0.41 ± 0.55 °C.
Conclusion:
In the absence of a gold standard, for scenarios where real-time monitoring is not required, using the iButton with its base applied to the skin is therefore recommended. To enhance the Flex sensor's accuracy, implementing a calibration protocol before use is strongly suggested, enabling its full potential for real-time monitoring.
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...