Changes in retinal vessel oxygen saturation using automated retinal oximetry in patients with significant carotid
Petr Polidar1,2,3, Barbora Pašková4,5, Marta Karhanová4,5
1Department of Neurology, University Hospital Olomouc, Olomouc, Czechia.
Purpose:
To evaluate the dynamics of changes in retinal oximetry parameters in patients with haemodynamically significant carotid stenosis.
Methods:
In this case-control study we examined 74 eye artery pairs in 37 patients with significant carotid stenosis over 50% using retinal oximetry. Fourteen eye artery pairs were excluded due to contraindications for oximetry or presenting carotid occlusion. From the remaining 60 eye artery pairs, 39 eye artery pairs formed the case group, remaining 21 pairs formed control group. Only 16 patients were eligible for bilateral testing to eliminate the possible influence of systemic comorbidities. Linear multiparametric model was used to predict the impact of the stenosis severity on retinal oximetry in context of systemic comorbidities.
Results:
Paired testing did not show any significant change in AV difference between stenotic and non-stenotic sides in 16 patients eligible for bilateral testing. The predictive model estimated weak correlation between increasing AV difference in increasing stenosis severity, with significant influence of atrial fibrillation and systemic atherosclerosis among noted comorbidities.
Conclusion:
The relationship between oxygen extraction in retina and increasing severity of the carotid stenosis is weak and modified by various individual factors, notably comorbidities.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:18Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...