Quantitative Lateral Flow Assay for Meropenem Determination: A Proof-of-Concept Study
Vasin Vasikasin1,2, Alaa Riezk1, Richard C Wilson1,3
1Centre for Antimicrobial Optimisation, Imperial College London, London SW7 2AZ, U.K.
A new lateral flow assay (LFA) enables rapid, point-of-care monitoring of Meropenem antibiotic levels. This innovative method offers a faster alternative to traditional techniques for optimizing critical care patient dosing.
Area of Science:
- Biochemistry
- Analytical Chemistry
- Pharmacology
Background:
- Therapeutic drug monitoring (TDM) is crucial for effective antibiotic treatment, especially in critically ill patients.
- Conventional methods like LC/MS for antibiotic quantification are time-consuming, hindering timely dose adjustments.
- Rapid and accurate TDM is needed to optimize patient outcomes and reduce antimicrobial resistance.
Purpose of the Study:
- To adapt a novel competitive lateral flow assay (LFA) for the rapid quantification of Meropenem.
- To evaluate the performance of the LFA using a beta-lactam receptor protein and a custom image analysis algorithm.
- To assess the potential of this LFA platform for point-of-care antibiotic monitoring.
Main Methods:
- Development of a competitive lateral flow assay (LFA) using BlaR-CTD protein and biotinylated BSA-Meropenem-conjugated gold nanoparticles.
- Adaptation of a dual test line LFA format previously validated for vancomycin.
- Quantification of Meropenem concentrations using a custom image analysis algorithm to measure test line intensities.
Main Results:
- The developed LFA demonstrated a concentration-dependent change in test line intensities for Meropenem.
- A strong correlation (R^2 = 0.9537) was observed between LFA results and Meropenem concentrations.
- The assay shows promise for rapid, point-of-care antibiotic quantification.
Conclusions:
- The novel LFA platform offers a potential solution for rapid Meropenem monitoring, overcoming limitations of conventional methods.
- This technology has the potential for broad application in diverse healthcare settings for point-of-care testing.
- Further optimization is required for improved accuracy at low Meropenem concentrations, but the proof-of-concept is strong for other beta-lactams.