Related Experiment Video
Updated: Jan 14, 2026

Transcanalicular Diode Laser-assisted Dacryocystorhinostomy for the Treatment of Primary Acquired Nasolacrimal Duct Obstruction
Published on: October 13, 2017
Functioning conjunctivodacryocystorhinostomy fistula following Pyrex tube extrusion: report of two cases
Rana F Alhumaemydi1, Rahaf J Altwijri1, Mostafa M Diab1,2,3
1Department of Ophthalmology, College of Medicine, King Saud University, Riyadh, Saudi Arabia.
Abstract:
Conjunctivodacryocystorhinostomy (CDCR) with Jones tube placement is a standard treatment for symptomatic canalicular obstruction but often complicated by tube extrusion. We report two rare cases where patients maintained a patent, functional ostium following Jones tube loss or removal. Both patients had a history of multiple lacrimal surgeries. After tube extrusion or removal, endoscopic assessments and follow-up confirmed continued tear drainage without recurrent epiphora. These cases demonstrate that, under certain conditions, CDCR tracts can remain stable and functional without stenting.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...