1Department of Cardiology, Institut Mutualiste Montsouris, Paris, France. edouard.simeon@rythmopole.paris.
Background:
Pulsed field ablation (PFA) has emerged as a non-thermal, tissue-selective modality for pulmonary vein isolation (PVI) in atrial fibrillation (AF) treatment, potentially minimizing collateral damage to adjacent structures. The VARIPULSE™ PFA system, integrated with the CARTO™ 3 electroanatomical mapping system, facilitates real-time catheter visualization, enabling procedures with minimal or no fluoroscopy. The objective is to evaluate the feasibility and acute safety of performing zero-fluoroscopy AF catheter ablation using the VARIPULSE™ PFA system in a cohort of consecutive patients with paroxysmal or persistent AF for 1 year.
Methods:
A prospective, single-center study was conducted involving consecutive patients undergoing AF ablation (PVI ± linear ablations) with the VARIPULSE™ system. Procedures were guided exclusively by the CARTO™ 3 system, without the use of fluoroscopy as well as intracardiac echocardiography (ICE). Data on procedural parameters, acute success rates, and complications were collected and analyzed.
Results:
A total of 121 consecutive patients were included in the study during 1 year with 60% of paroxysmal AF. Additional extra-pulmonary vein ablation (CTI or posterior wall isolation or both) was performed in 93 patients (76.9%). The mean time procedure was 44.5 ± 15.2 min and the success rate of zero-fluoroscopy was 98.4%. Two patients had an acute complication (1 TIA and 1 cardiogenic shock).
Conclusion:
This study demonstrates the feasibility, safety, and time-efficiency of a fully standardized fluoroscopy-free workflow, including posterior wall and CTI ablation. The use of TEE instead of ICE enhances cost-efficiency, potentially facilitating broader adoption of the protocol. However, the single-center nature of the study and the lack of a comparative fluoroscopy group represent important limitations.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System IV: CMRI