Related Experiment Video
Updated: Jan 14, 2026

Author Spotlight: Unraveling the Impact of Mechanical Ventilation on Diaphragm Function and Patient Outcomes
Published on: November 3, 2023
Combined Ultrasound Measurements of Diaphragm and Intercostal Muscles in Mechanically Ventilated Patients with
Chenliang Sun1,2, Kaihao Yuan3, Nana Yang2
1Jiangsu Provincial Key Laboratory of Critical Care Medicine, Department of Critical Care Medicine, Zhongda Hospital, School of Medicine, Southeast University, Nanjing 210009, China.
Abstract:
AimTo evaluate the efficiency of combined diaphragm and intercostal muscle ultrasound assessment in predicting the extubation outcome in mechanically ventilated patients with sepsis.MethodsThis study was a prospective observational study of septic patients consecutively admitted to the hospital from October 2022 to October 2023 for mechanical ventilation. During the period when the patients passed the ventilator weaning screening and spontaneous breathing trial (SBT), ultrasound evaluation of the diaphragm and intercostal muscles was performed to measure diaphragm excursion (DE), diaphragm thickening fraction (TFD) and intercostal muscle thickening fraction (TFic). The patients were divided into the successful extubation group (89 cases) and the failed extubation group (15 cases) according to the extubation results. ROC curves were used to analyze the effects of diaphragm ultrasound and intercostal muscle ultrasound alone and in combination to predict extubation outcomes.ResultsTFic and TFic/TFD values were significantly higher in the failed extubation group than in the successful extubation group during extubation (P < 0.05). The area under the ROC curve (AUROC) of DE, TFD, and TFic to predict extubation failure in mechanically ventilated patients with sepsis before extubation were 0.689, 0.657, and 0.769, respectively, whereas the combined indexes, such as TFic/TFD and TFic &TFD_mix had AUROCs of 0.867 and 0.860, respectively. TFic/TFD with a cutoff value of >0.95, had a sensitivity of 86.7% and specificity of 75.3% in predicting extubation failure, and TFic &TFD_mix with a cutoff value of >0.13, had a sensitivity of 86.6% and specificity of 80.9% in predicting extubation failure. Conclusion: The combination of diaphragm and intercostal muscle ultrasound assessment might effectively predict the extubation outcome in mechanically ventilated patients with sepsis.
More Related Videos
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...

