Purpose:
Many deep generative models have been proposed to reconstruct pseudo-healthy images for anomaly detection. Among these models, the variational autoencoder (VAE) has emerged as both simple and efficient. Although significant progress has been made in refining the VAE within the field of computer vision, these advancements have not been extensively applied to medical imaging applications.
Approach:
We present a benchmark that assesses the ability of multiple VAEs to reconstruct pseudo-healthy neuroimages for anomaly detection in the context of dementia. We first propose a rigorous methodology to define the optimal architecture of the vanilla VAE and select through random searches the best hyperparameters of the VAE variants. Relying on a simulation-based evaluation framework, we thoroughly assess the ability of 20 VAE models to reconstruct pseudo-healthy images for the detection of dementia-related anomalies in 3D brain -fluorodeoxyglucose (FDG) positron emission tomography (PET) and compare their performance.
Results:
This benchmark demonstrated that the majority of the VAE models tested were able to reconstruct images of good quality and generate healthy-looking images from simulated images presenting anomalies.
Conclusions:
Even if no model clearly outperformed all the others, the benchmark allowed identifying a few models that perform slightly better than the vanilla VAE. It further showed that many VAE-based models can generalize to the detection of anomalies of various intensities, shapes, and locations in 3D brain FDG PET.
More Related Videos
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography