Related Experiment Video
Updated: Jan 14, 2026

Non-invasive Assessments of Subjective and Objective Recovery Characteristics Following an Exhaustive Jump Protocol
Published on: June 8, 2017
Differences in Average Power Output Values from Computational Models of Repeated Vertical Jump Tests: A Single-Group
Vlad Adrian Geantă1,2, Pierre Joseph de Hillerin1,3, Alexandra Reta Iacobini1,4
1Doctoral School of Sport Science and Physical Education, Pitesti University Center, National University of Science and Technology Politehnica Bucharest, 110040 Pitesti, Romania.
None:
Background: Repeated vertical jump tests are widely used to assess neuromuscular function and lower limb performance. However, inconsistent formulas for average power output produce large discrepancies, limiting comparability across studies and limiting practical applications. This study aimed to compare three different models for the calculation of average power output, Bosco, Miron Georgescu (MG), and Modified Miron Georgescu-15s (MGM-15), applied to identical jump test data, in order to evaluate their computational behavior and practical relevance in athlete performance profiling. Methods: A single-group quasi-experimental study was conducted with 25 physically active male university students (mean age: 21.4 ± 2.7 years), who performed a 15 s repeated vertical jump test on the OptoJump Next system. Raw parameters including flight time, contact time, and jump height were recorded and exported. Average power output (W/kg) was subsequently calculated using three distinct computational models, each applied to the same dataset of flight and contact times. A repeated-measures ANOVA was used to compare outputs across models, with Bonferroni-adjusted pairwise comparisons for post hoc analysis (α = 0.05). Results: Significant differences were observed (p < 0.001). The Bosco model produced the highest values of average power (40.13 ± 8.56 W/kg), followed by MG (21.07 ± 5.92 W/kg), while MGM-15 yielded the lowest and most consistent outputs (4.08 ± 0.61 W/kg). Effect sizes were very large (η2p = 0.952), confirming that calculation models strongly influenced the outcomes. Conclusions: The findings demonstrate that average power output differed markedly across formulas, despite identical performance data. Bosco and MG models tended to overestimate values due to simplified assumptions, whereas the MGM-15 method produced lower and more consistent outputs that may better capture repeated jump demands. The standardization of computational models is fundamental to ensure comparability and to improve athlete performance profiling in research and practice.
More Related Videos
Related Concept Videos
Power
Comparing Experimental Results: Student's t-Test
Average Power
One-Way ANOVA: Equal Sample Sizes
Different sample means can result in different values for the variance estimate: variance between samples. This is because the variance between samples is calculated as the product of the sample size and the variance between the...
One-Way ANOVA: Unequal Sample Sizes
Comparing the Survival Analysis of Two or More Groups

