Identifying and minimizing primary sources of temporal broadening in online affinity micro free-flow electrophoresis
Gretchen S Burke1, Michael T Bowser1
1Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, USA. bowser@umn.edu.
Abstract:
Affinity micro free-flow electrophoresis (μFFE) takes advantage of continuous separations to enable real-time measurements in biological systems. Competitive immunoassay reagents are mixed online and streamed into the μFFE device, where bound and free labelled species are separated in real-time based on their electrophoretic mobility. In the current manuscript we optimized the affinity μFFE platform to minimize the response time of the assay. Analyte response time was improved by (1) mitigating temporal broadening as analyte transited the fluidic system and (2) reducing surface adsorption. Fast iteration of the microfluidic parameters enabled optimization of temporal broadening due to longitudinal diffusion and parabolic flow. Minimizing incubation capillary length while ensuring adequate equilibration time for the competitive immunoassay improved rise times from 25-seconds to 9-seconds, a 2.7-fold improvement in temporal response. The response time of the assay worsened when immunoassay reagents were incorporated due to peptide surface adsorption. Dynamic coating with 0.005% w/v bovine serum albumin was shown to mitigate surface adsorption without interfering with the binding and separation of the immunoassay components, resulting in 2.8-fold improvement in overall signal and 2-fold improvement in temporal response, which improved from 61 seconds to 30 seconds.
More Related Videos
12:05A Simple, Robust, and High Throughput Single Molecule Flow Stretching Assay Implementation for Studying Transport of Molecules Along DNA
Published on: October 1, 2017
09:58An Optimized Protocol for Electrophoretic Mobility Shift Assay Using Infrared Fluorescent Dye-labeled Oligonucleotides
Published on: November 29, 2016
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Electrophoresis: Overview
There...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...
Capillary Electrophoresis: Instrumentation
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...