Simultaneously calibrate and detect multiple analytes to offset the effects of co-existing regents and environmental
Chu Cheng1, Bingyan Jiang1, Hongyu Chen1
1Pen-Tung Sah Institute of Micro-Nano Science & Technology, Xiamen University, Xiamen, 361005, China.
Background:
The real water bodies contain varieties of contaminants and varying with time and climate, for which a fast and accurate in-situ approaching for simultaneously detecting multiple pollutants would be urgently on demand. Although the differential pulse voltammetry (DPV) gives a promising approach for simultaneous detection of multiple pollutants due to the high-resolution characteristic oxidation-reduction peak of target pollutants, it is very sensitive to the unpredictable environmental fluctuations, which should be addressed through specific anti-interference techniques based on synchronously achieved data.
Results:
A multi-pollutants simultaneous calibration and detection (MSCD) strategy and corresponding electrochemical sensors were proposed. Combined with the characteristic scanning potentials of analytes, a series of diluted or analyte-added water samples were detected, and a linear regression algorithm is developed to reduce the errors caused by interfering substances, unpredictable environmental fluctuations. Applied in the detection of 40-100 μM nitrite (NO2-) and 100-400 μM sulfite (SO32-), MSCD strategy has exhibited acceptable anti-interference to pH, temperature fluctuations and high concentration of interfering substances. In addition, the relative errors of multiple repeat measurements of nitrite and sulfite do not exceed 8.2 % and -8.3 %, respectively. When using different MSCD sensors, the relative errors were less than -11.6 % and 3.9 %, due to offsetting the deviation of fabrication batches. In the detection of actual water samples, the relative error is less than ±7.8 %, and proved to be significantly more accurate than commonly used electrochemical methods.
Significance:
Compared with commonly used laboratory calibration methods, the proposed MSCD strategy exhibits excellent anti-interference performance in co-pollutant matrices with pH fluctuations and temperature changes. This MSCD strategy is expected to adapt to various electrochemical targets with appropriate sensing materials and provide an alternative option for simultaneously detecting multiple pollutants with high accuracy and repeatability.
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
High-Performance Liquid Chromatography: Types of Detectors
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...