Low Driveline Infection Rates in Patients With a Novel Fully Magnetically Levitated Ventricular Assist Device
Xianqiang Wang1, Xingtong Zhou1, Haibo Chen1
1Centre of Cardiac Surgery in Adults, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100037, China.
Objectives:
Driveline infection remains a major complication of long-term ventricular assist device therapy. Previous studies have associated the risk of infection with driveline design and physical properties. The CH-VAD is a fully magnetically levitated pump with an ultrathin (diameter 3.3 mm), highly flexible driveline designed to reduce infection risk. This study was conducted to assess the incidence, risk factors, and approaches to prevention and management of driveline infection in CH-VAD patients (NCT06878456).
Methods:
All patients who underwent CH-VAD implantation between June 2017 and October 2024 at 9 centres were retrospectively analysed. Data related to clinical characteristics, surgical procedures, and driveline infection prevention and management details were collected, and risk factors were analysed.
Results:
A total of 181 consecutive patients were included, with a median age of 56 years and 86% male. During a median support duration of 1.6 years, driveline infections occurred in 20 out of 181 patients (11.0%). Twenty-six events were observed, corresponding to a rate of 0.07 events per patient-year. Cumulative incidence of the first driveline infection was 2.8% at 6 months, 5.6% at 12 months, and 8.5% at 24 months. Frequent dressing changes were found to be significantly associated with increased driveline infection risk (HR 3.773, P = .022).
Conclusions:
Patients treated with CH-VADs experienced an encouraging low rate of driveline infection, considered among the lowest reported for durable ventricular assist devices. These findings have implications for both clinical management and driveline design.
Related Concept Videos
Cardiomyopathy V: Interprofessional Care
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Mitral Stenosis III: Medical Management
Cardiac Catheterization IV: Nursing Management