Related Experiment Video
Updated: May 4, 2026

Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Migration of ingested fish bone and toothpick focusing on comparative clinicoradiological findings and analysis of
Wanting Zheng1, Xiaojia Wu1, Harshal Ripal Karia2
1The First Affiliated Hospital, Shantou University Medical College, Shantou, China.
Introduction:
Ingested sharp foreign body (FB) such as fish bones and toothpicks are a relatively rare event, but may migrate to adjacent or distant organs resulting in serious complications and challenging to diagnose. The aim of this paper is to review the literature about the comparative analysis of clincoradiological findings between migratory fish bones and toothpicks and investigated the frequency and associated factors of diagnostic errors.
Materials And Methods:
Our review search identified a total of 96 studies with 107 patients containing case reports of ingested migratory fish bones and toothpicks. We then performed a comparative analysis of patients' characteristics, medical history, diagnostics, therapy, and clinical outcome.
Results:
Among 107 reported cases, 85 (79.4%) involved migrating fish bones and 22 (20.6%) involved toothpicks. The peritoneal cavity was the most common migration site (69/107; 64.5%). Notably, 57.9% of patients (62/107) did not report FB ingestion on admission, and only ten (9.3%) recalled ingestion after postoperative evaluation. Severe complications were observed in 26.2% of cases (28/107). Diagnostic errors occurred in 15 cases (14.0%), with eight missed by imaging and seven misdiagnosed as inflammatory lesions or tumors. Significant differences were noted between fish bones and toothpicks in location, severe complications, and mean length (all P < 0.05).
Conclusions:
Ingested migratory fish bones or toothpicks are a medical emergency capable of causing significant complications, highlighting their importance as a critical differential diagnosis. The diagnostic strategy should prioritize heightened clinical awareness, a detailed history of FB ingestion, and the use of multiplanar reconstruction CT in conjunction with ultrasound.
Related Concept Videos
X-ray Imaging
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation I: X-ray and CT

