Related Experiment Video
Updated: Jan 14, 2026

Collecting Saliva and Measuring Salivary Cortisol and Alpha-amylase in Frail Community Residing Older Adults via Family Caregivers
Published on: December 18, 2013
Saliva Collection Methods and Storage Conditions Affect Salivary Iodine Concentration: Recommendations for Optimal
Fei Li1, Duan Li1, Hexi Zhang1
1Department of Nutrition and Food Hygiene, School of Public Health, Tianjin Medical University, Tianjin, China.
Background:
Salivary iodine concentration (SIC) has been demonstrated to apply to iodine nutrition assessment. However, limited research exists on saliva collection and storage methods, which are essential for reliable measurements of SIC.
Objectives:
This study aims to investigate the effects of various saliva sample collection and storage methods and to establish standardized protocols.
Methods:
Healthy adults were randomly recruited from the university. This study was designed with 2 components: collection methods and storage conditions. Participants provided 4 saliva samples each under stimulation and mouthwash conditions for the collection method analysis. Regarding storage conditions, a 5-mL saliva sample was collected and divided into 4 portions. One portion underwent analysis within 24 h, whereas the remaining 3 were stored at -80°C, -20°C, and 4°C, respectively. SIC detection was performed after 7, 90, 180, and 365 d of storage.
Results:
Compared with natural secretion, SIC significantly decreased by 21.44 μg/L [95% confidence interval (CI): -33.74, -9.14] after olfactory stimulation, by 17.74 μg/L (95% CI: 26.06, -9.43) after mechanical stimulation, by 74.37 μg/L (95% CI: -85.31, -63.44) after chewing stimulation, and by 23.90 μg/L (95% CI: -31.00, -16.79) 1 min after rinsing. No significant change was observed after rinsing for 5 and 10 min (P > 0.05). Compared with timely testing, SIC remained stable at -80°C for 365 d (all P > 0.05). However, at -20°C, SIC significantly decreased by 20.8 μg/L (95% CI: -37.7, -3.79) after 180 d, and by 26.9 μg/L (95% CI: -43.9, -9.81) after 365 d. At 4°C, SIC significantly increased by 25.8 μg/L (95% CI: 5.49, 46.2) after 365 d.
Conclusions:
This study recommends collecting saliva through natural secretion 5 min after rinsing. For long-term storage (≥180 d), samples should be preserved at -80°C. For short-term storage (≤90 d), they may be stored at -80°C, -20°C, or 4°C.
More Related Videos
Related Concept Videos
Redox Titration: Iodimetry and Iodometry
Sample Handling
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
Precipitation Titration Curve: Analysis